【24h】

Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison.

机译:鹰嘴骨折与FiberWire或修理金属丝张力带:一个生物力学比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Tension band constructs are commonly used for olecranon fracture fixation. The purpose of this study was to determine if a tension band constructed of FiberWire (Arthrex, Naples, FL), a high-strength polyester and polyethylene suture, will provide fixation that is equivalent to an 18-gauge metal wire tension band. METHODS: The following 4 fixation methods were biomechanically tested in cadaveric elbows with a simulated transverse olecranon fracture: (1) Kirschner wires (K-wires) with an 18-gauge metal wire tension band, (2) K-wires with a FiberWire tension band, (3) intramedullary screw with an 18-gauge metal wire tension band, and (4) intramedullary screw with a FiberWire tension band. Each elbow underwent all 4 repair methods. The K-wire repairs were performed first followed by the intramedullary screw repairs. The order of the tension band (FiberWire or metal wire) was randomly assigned. Specimens were tested under cyclic loading conditions that simulated stresses generated by (1) active range of motion and (2) pushing up from a chair. Fracture displacement was recorded by using transducers placed at the articular surface of the fracture and on the posterior surface of the olecranon. RESULTS: There were no significant differences in fracture displacement associated with the use of a high-strength suture or metal wire tension band under conditions simulating active range of motion or a more vigorous physiologic stress. Also, there were no significant differences associated with the use of an intramedullary screw versus K-wire fixation under either condition. CONCLUSIONS: The biomechanical characteristics of high-strength suture tension bands are equivalent to 18-gauge metal wire tension bands when used with either an intramedullary screw or K-wires. The fatigue patterns of high-strength suture tension bands and metal wire tension bands are similar. There is not a significant difference between the biomechanical strength of intramedullary screw fixation constructs and K-wire constructs. CLINICAL RELEVANCE: FiberWire tension bands may be used in place of metal wire tension bands without sacrificing fixation strength.
机译:目的:张力带构造是常用的鹰嘴骨折固定。本研究旨在确定一个张力乐队由FiberWire (Arthrex、那不勒斯、FL)高强度聚酯,聚乙烯缝合,将提供相当于一个固定吗18-gauge金属钢丝张力带。后4固定方法提高成绩测试与模拟尸体肘部横向鹰嘴骨折:(1)柯式电线(K-wires) 18-gauge金属线张力带,(2)K-wires FiberWire张力带,(3)髓内螺钉18-gauge金属钢丝张力带、(4)髓内钉FiberWire张力乐队。钢丝的维修进行了第一次之后由髓内螺旋维修。张力带(FiberWire或金属线)随机分配。循环荷载条件,模拟压力(1)产生的积极的活动范围和(2)从椅子上推。记录通过使用传感器放置在吗骨折和关节面后表面的鹰嘴。没有明显差异的骨折位移与使用有关高强度缝合或金属钢丝张力带条件下模拟活动的范围运动或一个更有活力的生理压力。另外,没有明显差异与髓内的使用有关螺杆与下钢丝固定条件。高强度的特征缝合张力乐队相当于18-gauge金属线当使用一个紧张的乐队髓内钉或K-wires。高强度缝合张力带的模式和金属钢丝张力带是相似的。不是一个重要的区别髓内钉的生物力学强度固定结构和钢丝结构。临床相关性:FiberWire张力乐队用于金属丝张力带的地方在不牺牲固定强度。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号