首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Biomechanical comparison of figure-of-8 versus cylindrical tibial inlay constructs for arthroscopic posterior cruciate ligament reconstruction.
【24h】

Biomechanical comparison of figure-of-8 versus cylindrical tibial inlay constructs for arthroscopic posterior cruciate ligament reconstruction.

机译:生物力学比较figure-of-8和圆柱形胫骨镶嵌结构关节镜后交叉韧带重建。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine the biomechanical strength of Achilles tendon allografts with 2 different bone plug configurations as prepared for arthroscopic posterior cruciate ligament reconstruction when fixed as tibial inlay constructs. METHODS: Nine matched pairs of cadaveric tibias were reconstructed by a standardized tibial inlay technique by use of either a cylindrical bone plug (12 mm in diameter) or a figure-of-8 bone plug (12 x 18 mm). Constructs were subjected to cyclic tensile loading followed by load to failure. The statistical analysis consisted of paired t tests with significance set at P < .05. RESULTS: No significant differences were found in yield load, ultimate load, stiffness, load at 5 mm, and total cyclic displacement between the groups. Although both constructs showed equivalent biomechanical properties, the tendons of the cylindrical bone plugs failed predominantly by shear off the bone compared with the figure-of-8 plugs, which failed by the sutures tearing through the tibial plateau. CONCLUSIONS: Tibial constructs with cylindrical and figure-of-8 bone plugs as prepared for use in arthroscopic posterior cruciate ligament reconstruction have comparable immediate biomechanical stability when fixed by a tibial inlay technique in a cadaveric model. CLINICAL RELEVANCE: Cylindrical and figure-of-8 bone plugs have comparable immediate biomechanical stability when fixed by a tibial inlay method, with the cylindrical technique being potentially technically easier to perform.
机译:目的:确定生物力学强度两个不同的同种异体跟腱骨塞配置准备关节镜后交叉韧带当固定重建胫骨镶嵌构造。尸体胫骨被一个重建利用标准化的胫骨镶嵌技术一个圆柱形骨塞(12毫米直径)或figure-of-8骨塞(12 x 18毫米)。加载之后,加载失败。统计分析包括配对t检验与意义P < . 05。在屈服载荷显著差异被发现,极限载荷、刚度、负载在5毫米,和总循环组之间的位移。两个构造显示相同的生物力学属性,圆柱形的肌腱骨插头失败主要通过剪断骨头而figure-of-8插头,失败了通过胫骨的缝合线撕裂高原。圆柱和figure-of-8骨插头准备在关节镜后使用交叉韧带重建有可比性直接当固定的生物力学稳定性胫骨镶嵌技术在尸体模型。临床相关性:圆柱和figure-of-8骨插头有比较直接的当胫骨固定的生物力学稳定性镶嵌方法,圆柱的技术技术上可能更容易执行。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号