首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Flexible instruments outperform rigid instruments to place anatomic anterior cruciate ligament femoral tunnels without hyperflexion
【24h】

Flexible instruments outperform rigid instruments to place anatomic anterior cruciate ligament femoral tunnels without hyperflexion

机译:灵活的仪器比刚性工具解剖前交叉韧带股骨隧道不屈曲过度

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: This study evaluated the ability of flexible instruments compared with rigid instruments to place anatomic femoral tunnels in anterior cruciate ligament reconstructions by use of both transtibial drilling and anteromedial drilling without hyperflexion. Methods: Rigid and flexible pins were placed in 12 matched pairs of cadaveric knees with transtibial drilling (6 pairs) and anteromedial drilling (6 pairs) at 110° of flexion. Intraosseous pin lengths, femoral exit locations, and tunnel alignment were measured. Results: Transtibial drilling with rigid pins placed relatively vertical femoral tunnels 5.8 ± 1.0 mm superior to the central anterior cruciate ligament insertion. Transtibial drilling with flexible pins placed tunnels in the center of the femoral attachment, but the tunnels were relatively close to the posterior femoral cortex, with a mean distance of 8.0 ± 5.9 mm (P <.05), compared with transtibial drilling with rigid pins. Anteromedial drilling resulted in central anatomic pin placements with rigid and flexible instruments. Tunnel lengths with flexible pins were longer (42.0 ± 7.2 mm) compared with tunnel lengths with rigid pins (32.5 ± 7.1 mm) (P <.01). Flexible pins exited farther from the posterior cortex compared with rigid pins (P <.01). In 3 of 6 knees with rigid pins, the exit point was at the posterior border of the femoral cortex. All flexible pins exited a safe distance from the posterior femoral cortex. Conclusions: Transtibial drilling with rigid instruments did not produce anatomic femoral tunnels. Transtibial drilling with flexible pins produced anatomic tunnels, but the tunnels were close to the posterior femoral cortex. Anteromedial drilling without hyperflexion produced anatomic tunnels by use of rigid and flexible instruments, but with flexible instruments, the tunnels were longer and were farther from the posterior femoral cortex. Anteromedial drilling with flexible pins produced tunnels with good length and the best position. Clinical Relevance: Flexible instruments compared with rigid instruments can facilitate the creation of anatomic femoral tunnels by use of anteromedial drilling without hyperflexion.
机译:目的:本研究评估的能力灵活的仪器与刚性仪器解剖股骨隧道的地方前交叉韧带重建的使用transtibial钻井和入没有屈曲过度开采。灵活的针被安置在12配对的尸体的膝盖transtibial钻井(6入组)和钻探(6条)110°弯曲。股出口位置和隧道对齐测量。刚性针放置相对垂直股隧道5.8±1.0毫米优于中央前交叉韧带插入。钻井与灵活的别针把隧道股附件的中心,但隧道相对接近股后皮层,平均距离为8.0±5.9毫米(P< . 05),而transtibial钻探严格的别针。中央解剖针与刚性和配售灵活的工具。灵活的针长(42.0±7.2毫米)与隧道长度与僵化的别针(32.5±7.1毫米)(P < . 01)。远离后皮质相比僵化的别针(P < . 01)。销,出口点的后缘股骨皮质的。安全距离后股骨皮质。结论:与刚性Transtibial钻探仪器没有产生解剖股隧道。生产解剖隧道,但隧道接近股后皮层。入钻不屈曲过度生产使用刚性和解剖隧道灵活的工具,但灵活仪器,隧道是长,远离股后皮层。入钻井与灵活的别针隧道长度和最好的位置。临床相关性:灵活的仪器相比与刚性工具可以方便创建解剖股骨隧道的使用入没有屈曲过度开采。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号