A study was performed to characterize hand extremity doses received by a laboratory researcher performing a metabolic cell labeling procedure using 10-cm-diameter cell culture dishes containing GBq amounts of 32P-orthophosphate. Specifically, the optimal location for placement of thermoluminescent dosimeters on the extremities was determined as was the phase (time frame) during the cell labeling procedure when the highest dose was received. The cell labeling procedure was divided into four phases. Thermoluminescent dosimeters were placed on three fingers of each hand at the start of each phase and after the completion of that phase, collected, and sent to the processor. It was determined that in the case of this right-handed worker, the left-hand index finger should be used for determining the maximum extremity dose. The time frame during which the highest extremity dose was received was the cell lysis phase. Acrylic shielding was fabricated, which significantly reduced worker extremity dose.
机译:一项研究进行了描述肢体剂量收到实验室研究人员执行代谢细胞标记使用10-cm-diameter细胞培养过程包含GBq大量的菜肴32 p-orthophosphate。热释光的位置放置测试仪在四肢决心是一个阶段(时间)在细胞标签程序最高剂量时收到。分为四个阶段。被放置在每只手的三根手指每个阶段的开始和完成后阶段,收集和发送到处理器。这是对于这个决定的右撇子的工人,左手食指应该用于确定最大肢体剂量。收到极端最高剂量的细胞裂解阶段。显著降低工人肢体吗剂量。