【24h】

Clinical and Radiologic Outcomes After Meniscus Allograft Transplantation at 1-Year and 4-Year Follow-up

机译:半月板后临床和影像学结果同种异体移植物移植1年和4年后续

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To assess the clinical and radiologic outcomes of meniscus allograft transplantation (MAT) with serial evaluation at 1 year and at 4 years. Methods: Among 151 patients who received MAT between March 2006 and June 2009, we prospectively recruited the patients who had undergone clinical and radiologic examinations at 1 year after the operation. The Lysholm score, International Knee Documentation Committee score, and Knee Society Score were determined. Plain radiography was used for evaluation of osteoarthritis, and magnetic resonance imaging (MRI) was used to assess the cartilage status and meniscal extrusion. Results: Thirty-nine patients with a mean age of 40 +/- 9 years were recruited. The first visit was conducted at a mean of 13.6 months (range, 11 to 17 months) postoperatively, and the last visit was conducted at a mean of 50.4 months (range, 48 to 72 months) postoperatively. Of the patients, 29 were men. The lateral side was involved in 27 patients. The Lysholm knee score increased to a median value of 89 (range, 75 to 100) at the first visit and 88 (range, 76 to 100) at the second visit from a preoperative median value of 79 (range, 37 to 99), which was statistically significant according to the Kruskal-Wallis test. According to the Kellgren-Lawrence grade based on anteroposterior radiographs, 21 patients (54%) showed no arthrosis progression and the overall status of arthrosis on anteroposterior radiographs was significantly changed (P <.001). On MRI, 25 patients (64%) showed no cartilage status change and the overall status was not changed significantly (P = .178). The meniscal extrusion extent was 4.2 +/- 0.4 mm at the first visit and 4.2 +/- 0.6 mm at the second visit (P = .678), and the relative percentage of extrusion was 0.44 +/- 0.16 and 0.51 +/- 0.21, respectively (P = .059). The subgroup in which arthrosis had progressed on MRI showed a larger amount of change in the relative percentage of extrusion (P = .023). No correlation was observed between meniscal extrusion and various outcomes. Conclusions: Repeat assessment at 4 years showed that MAT showed improvement in knee function, but it had decreased over time. Considerable meniscal extrusion was observed, but it did not increase during follow-up and did not show any correlation with other outcomes. Extrusion progression showed significant correlation with arthrosis progression.
机译:目的:评估临床和放射异体半月板移植的结果(垫)系列评价1年和4年。2006年3月和2009年6月之间垫,我们前瞻性招募患者经历了临床和影像学检查手术后1年。国际委员会膝盖文档得分,社会和膝关节评分测定。射线照相法是用于评估骨关节炎和磁共振成像(MRI)被用来评估软骨和地位半月板挤压。平均年龄为40 + / - 9年被招募。第一次访问是由平均为13.6个月(范围,11到17个月)术后,最后进行访问的意思50.4个月(范围,48 - 72个月)术后。外侧参与了27个病人。Lysholm膝盖得分的中值增加89(范围,75年至100年)在第一次访问和88年(从76年到100年)的第二次访问术前平均79(范围,37的价值99年),在统计学上意义重大根据克鲁斯卡尔-沃利斯检验。Kellgren-Lawrence年级基础上前后的射线照片,21例(54%)没有显示关节和整体发展的地位在前后的关节射线照片明显改变(P <措施)。在核磁共振,25例(64%)显示没有软骨状态变化和总体状况没有改变明显(P = .178)。挤压程度为4.2 + / - 0.4毫米在第一访问和4.2 + / - 0.6毫米的第二次访问(P =.678)和挤压的相对比例是0.44 + / - 0.16和0.51 + / - 0.21,分别吗(P = .059)。更大的进步在MRI显示改变挤压的相对百分比(P= 0)。半月板挤压和各种结果。结论:在4年显示重复评估垫显示膝关节功能改善,但随着时间的推移已经减少。观察挤压,但它并没有增加在随访中,没有任何相关性与其他结果。与关节显著相关进展。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号