首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >The assessment of the effect of thyroid size and shape on the activity estimate using Monte Carlo simulation.
【24h】

The assessment of the effect of thyroid size and shape on the activity estimate using Monte Carlo simulation.

机译:评估的影响甲状腺大小和形状的活动使用蒙特卡罗估计模拟。

获取原文
获取原文并翻译 | 示例
           

摘要

Monte Carlo simulations have been used to assess the uncertainty introduced into an activity estimate of radioiodine (125I and 131I) in the thyroid when the size and shape of the gland differs from that of the calibration phantom. The detector dimensions for the 125I simulations were small (diameter 2.54 cm, thickness 0.2 cm); medium (diameter 7.62 cm, thickness 0.2 cm); large (diameter 30.48 cm, thickness 0.2 cm). The detector dimensions for the 131I simulations were small (diameter 2.54 cm, thickness 3.2 cm); medium (diameter 7.62 cm, thickness 6.4 cm); large (diameter 30.48 cm, thickness 11.0 cm). Shapes simulated have included thyroid glands with a third (pyramidal) lobe, no isthmus, and rotated lobes. Sizes simulated have been 10 g, 20 g, and 40 g. The results show that the size of the uncertainty is dependent on the detector size, the neck-to-detector distance, and the type of radioiodine being measured (i.e., 131I or 125I). The worst case bias (on contact counting) for either 125I or 131I using the different sized detectors is as follows: small is between -40% and 40%; medium is between -33% and 17%; large is between -20% and 5%. If the detectors are placed at about 15 cm from the neck the bias values drop so that the uncertainty introduced if the subject has a smaller than standard thyroid becomes insignificant and becomes much improved if the thyroid is larger than the standard. The bias values for the detectors are as follows: small is between -20% and 5%; medium is between -23% and 2%; large is between -21% and 2%.
机译:蒙特卡罗模拟被用来评估不确定性引入一个活动估计的放射碘(125年和131年我)甲状腺腺体的大小和形状不同于校准的幻影。125我模拟探测器尺寸小(直径2.54厘米,厚度0.2厘米);介质(直径7.62厘米,厚度0.2厘米);大(直径30.48厘米,厚度0.2厘米)。131我模拟探测器尺寸小(直径2.54厘米,厚度3.2厘米);介质(直径7.62厘米,厚度6.4厘米);大(直径30.48厘米,厚度11.0厘米)。形状模拟包括甲状腺腺体第三个(锥体)叶,没有地峡,叶旋转。40 g, g。不确定性是依赖于探测器大小、neck-to-detector距离和类型放射碘被测量(例如,131我或125我)。125年或131年,我使用的是不同的大小探测器如下:小到-40%和40%;在-20%和5%之间。约为15厘米从颈部偏差值下降如果主题引入的不确定性有一个小于标准甲状腺变成了无关紧要,成为改进的如果甲状腺大于标准。值探测器如下:小在-20%和5%之间;2%;

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号