摘要

Radiosynovectomy is a widely available therapeutic option that involves radiopharmaceutical injections into joints to treat rheumatoid arthritis. However, data on the beta-radiation dose equivalents for the staff performing such treatments are limited. The aim of this study was to determine the personal dose equivalents HP(0.07) to the skin of the hands of the treating physician under several exposure scenarios. An activity of 185 MBq Y was used. Thermoluminescence detectors were attached at the finger tip of the thumb, forefinger, and middle finger of the treating physician. Measurements of beta-exposures were made during treatment of 70 knees with Y under the following exposure scenarios: group 1, the radiosynovectomy was performed with syringe shield with Perspex (Plexiglas, Rohm GmbH, Germany) (thickness of 5 mm); group 2, additionally a manipulator was used for fixation of the needle; group 3, radiation-resistant gloves were added to the measures in groups 1 and 2. For group 1, the highest beta doses were measured at the forefinger (22.1 muSv MBq) (22,100 murem/27 muCi) and thumb with 16.5 muSv MBq (16,000 murem/27 muCi) at the left hand, which holds the needle (right-handed physician). In group 2, the radiation doses were reduced to 0.6 muSv MBq (60 murem/27 muCi) at the left forefinger and 0.5 muSv MBq (50 murem/27 muCi) at the left thumb. The use of a manipulator and special radiation resistant gloves reduced the radiation dose to 0.4 muSv MBq (40 murem/27 muCi) at the left forefinger and to 0.3 muSv MBq (30 murem/27 muCi) at the left thumb in group 3. It was concluded that while performing radiosynovectomy without a manipulator for fixation of the needle, the dose measured at the left forefinger could exceed the German limit of 500 mSv (50 rem) per year for the official dosimetry at the skin. Using holding forceps allows compliance with the legal limit and could considerably reduce the beta dose. The use of radiation-resistant gloves reduced the beta dose at the skin only slightly.
机译:Radiosynovectomy是一种广泛使用的治疗选项,包括放射性药物注入治疗风湿性关节关节炎。剂量当量等员工执行治疗方法是有限的。确定个人剂量当量惠普(0.07)的皮肤的治疗医生在几个暴露场景。活动185兆贝可Y。热释光探测器是附加的指尖的拇指,食指和中指,手指的治疗医生。beta-exposures进行治疗期间的70年膝盖与Y以下暴露场景:组1,radiosynovectomy表现与有机玻璃注射器的盾牌(有机玻璃,罗姆GmbH,德国)(厚度5毫米);固定针;防辐射的手套被添加到措施组1和2。β最高剂量的测定食指(22.1 muSv兆贝可)(22100 murem / 27 muCi)和拇指16.5 muSv兆贝可(16000 murem / 27muCi)在左手,握着针(右手医生)。辐射剂量减少到0.6 muSv兆贝可(60murem / 27 muCi)左食指和0.5muSv兆贝可(50 murem / 27 muCi)在左手拇指。使用机械手和特殊的辐射耐手套减少辐射剂量0.4 muSv兆贝可(40 murem / 27 muCi)在左边食指和0.3 muSv兆贝可(30 murem / 27 muCi)在左手拇指群3。,虽然radiosynovectomy没有表演机械手固定针的剂量以左食指可能超过德国每年500毫西弗(50 rem)极限的官方在皮肤剂量测定法。钳允许符合法定上限并能大大减少β剂量。使用防辐射的手套了在皮肤略β剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号