首页> 外文期刊>Health Physics: Official Journal of the Health Physics Society >Validation of ICNIRP estimates of toxicity thresholds for NIR (785 nm) light in the retinas of pigmented rabbits.
【24h】

Validation of ICNIRP estimates of toxicity thresholds for NIR (785 nm) light in the retinas of pigmented rabbits.

机译:验证ICNIRP毒性的估计阈值近红外光谱在视网膜光(785海里)色素的兔子。

获取原文
获取原文并翻译 | 示例
           

摘要

The International Commission on Non-Ionizing Radiation Protection (ICNIRP) established eye-safe exposure limits for laser light based on estimates of the 50% exposure dose (ED50) for retinal damage in animals. The ED50 has not been determined for continuous-wave near-infrared (NIR) light, as may be used in instruments for spectroscopic analysis of the eye. The purpose of this study is to determine the ED50 of 785-nm light delivered by a Raman spectroscopy instrument on the retinas of pigmented rabbits, and to compare that ED50 to the ICNIRP estimates. Light of varying power was focused into the anterior chambers of rabbits for 4, 20, or 300 s. Estimates of spot size on the retina were determined by modifying the schematic rabbit eye with actual axial length and refractive error measurements. Masked examiners determined retinal burns from fundus photographs and fluorescein angiograms made immediately after exposure and again 48-72 h later. Thirty-five of 86 exposed eyes had retinal burns. In 12 of thesethe burn was not visible until 48-72 h. In 6 the burn was visible on color photographs, but not on fluorescein angiography. The ED50 retinal power density from probit analysis was 14,513 mW cm(-2), 10,369 mW cm(-2), and 5,237 mW cm(-2) for 4-s, 20-s, and 300-s exposures, respectively. Thus, the ED50 for retinal burns from 785-nm light is approximately 7 and 7.5 times the ICNIRP permitted limits for 4- and 20-s exposures, and 5.6 times the limit for 300-s exposures. This is consistent with the ICNIRP intention to set power limits several times less than ED50.
机译:国际非电离委员会辐射防护(1)建立成对激光基于接触限度估计50%的照射剂量(ED50)视网膜损伤的动物。确定了连续波近红外(NIR)光,可用于仪器光谱分析。本研究旨在确定785 nm的ED50光由拉曼光谱仪器的视网膜色素兔子,和比较,ED50 ICNIRP估算。不同的权力集中到前室的兔子4、20或300年代。视网膜上的光斑大小的估计由修改示意图兔子的眼睛与实际的轴向长度和屈光不正测量。从眼底照片和荧光素燃烧血管造影后立即曝光和48 - 72 h后。眼睛视网膜灼伤。是不可见的,直到第六48 - 72 h。燃烧吗彩色照片上可见,但不是荧光素血管造影。从probit密度分析14513 mW厘米(2),(2),10369 mW厘米,5237 mW厘米(2)4 s, 20年代和300年代的风险敞口,分别。因此,视网膜灼伤的ED50从785 nm光大约是7和1的7.5倍允许限制为4 - 20年代曝光,5.6倍的极限300 - s曝光。符合ICNIRP意图集权力不到ED50限制几次。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号