The Internet's Role in a Biodosimetric Response to a Radiation Mass Casualty Event

机译:互联网在Biodosimetric反应中的作用一个辐射大规模伤亡事件

获取原文
获取原文并翻译 | 示例
           

摘要

Response to a large-scale radiological incident could require timely medical interventions to minimize radiation casualties. Proper medical care requires knowing the victim's radiation dose. When physical dosimetry is absent, radiation-specific chromosome aberration analysis can serve to estimate the absorbed dose in order to assist physicians in the medical management of radiation injuries. A mock exercise scenario was presented to six participating bio-dosimetry laboratories as one individual acutely exposed to ~(60)Co under conditions suggesting whole-body exposure. The individual was not wearing a dosimeter and within 2-3 h of the incident began vomiting. The individual also had other medical symptoms indicating likelihood of a significant dose. Physicians managing the patient requested a dose estimate in order to develop a treatment plan. Participating laboratories in North and South America, Europe, and Asia were asked to evaluate more than 800 electronic images ofmetaphase cells from the patient to determine the dicentric yield and calculate a dose estimate with 95% confidence limits. All participants were blind to the physical dose until after submitting their estimates based on the dicentric chromosome assay (DCA). The exercise was successful since the mean biological dose estimate was L89 Gy whereas the actual physical dose was 2 Gy. This is well within the requirements for guidance of medical management. The exercise demonstrated that the most labor-intensive step in the entire process (visual evaluation of images) can be accelerated by taking advantage of world-wide expertise available on the Internet.
机译:应对大规模核辐射事故可能需要及时的医疗干预措施吗减少辐射的伤亡。护理需要知道受害者的辐射剂量。radiation-specific染色体畸变分析可以估计的吸收剂量协助医生的医疗管理辐射损伤。提交给六bio-dosimetry参与作为一个个人敏锐地暴露于实验室~(60)有限公司条件下显示全身曝光。剂量计,2 - 3小时内的事件开始呕吐。症状表明一个重要的可能性剂量。为了开发一种治疗剂量估计计划。南美、欧洲和亚洲被要求评估超过800电子图像ofmetaphase细胞从病人来确定具双着丝的产量和计算剂量估算置信区间为95%。忽视物理剂量之前提交他们估计基于具双着丝的染色体测定(DCA)。平均生物剂量估算L89 Gy而实际的物理剂量是2 Gy。在指导的要求吗医疗管理。最在整个劳动密集型步骤过程(视觉评价的图像)加速了全球利用专业知识在互联网上可用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号