The urinary excretion and wound retention data collected after a Pu-238-contaminated wound were analyzed using Markov Chain Monte Carlo (MCMC) to obtain the posterior distribution of the intakes and doses. An empirical approach was used to model the effects of medical treatments (chelation and excision) on the reduction of doses. It was calculated that DTPA enhanced the urinary excretion, on average, by a factor of 17. The empirical analysis also allowed calculation of the efficacies of the medical treatments-excision and chelation averted approximately 76% and 5.5%, respectively, of the doses that would have been if there were no medical treatment. All bioassay data are provided in the appendix for independent analysis and to facilitate the compartmental modeling approaches being developed by the health physics community.
机译:尿排泄和伤口保留数据pu - 238后收集被污染的伤口分析了利用马尔可夫链蒙特卡罗(密度)获得后验分布的摄入量和剂量。模型医学治疗的影响(螯合和切除)在减少剂量。尿排泄,平均17倍。实证分析还允许计算医疗的功效treatments-excision和螯合避免分别约76%和5.5%剂,如果没有治疗。在独立分析和附录促进区划的建模方法正在开发的物理健康社区。