首页> 外文期刊>ECS transactions >Investigation of HT-PEFCs by Means of Synchrotron X-ray Radiography and Electrochemical Impedance Spectroscopy
【24h】

Investigation of HT-PEFCs by Means of Synchrotron X-ray Radiography and Electrochemical Impedance Spectroscopy

机译:调查HT-PEFCs通过同步x光射线照相法和电化学阻抗光谱学

获取原文
获取原文并翻译 | 示例

摘要

Differently conditioned high temperature polymer electrolyte fuel cells (HT-PEFCs) were investigated by electrochemical impedance spectroscopy to study the influence of the break-in procedure on the overall fuel cell performance during the heating-up procedure as well as during different operating conditions. It is shown that a classical 70 h break-in procedure leads to the best fuel cell performance compared to fuel cells which are used after a rapid break-in or rather without any break-in procedure. A combination of synchrotron X-ray radiographic measurements with in-situ performed time-dependent impedance spectroscopy was used to investigate the de-/hydration processes within the electrolyte of the membrane electrode assembly (MEA) components of a dynamically operated HT-PEFC. This helps to understand the fuel cell performance under different operating conditions.
机译:不同条件高温聚合物电解质燃料电池(HT-PEFCs)研究了电化学阻抗光谱学研究的影响磨合过程对整个燃料电池性能在升温过程以及在不同的操作条件。表明一个经典70 h磨合过程导致最佳的燃料电池性能比较燃料电池,使用后迅速磨合或者说没有任何磨合过程。射线照相测量与现场执行时间阻抗光谱被用来调查de - /水化过程中膜电极的电解液一个动态的组装(MEA)组件HT-PEFC操作。燃料电池不同操作条件下的性能条件。