首页> 外文期刊>Applied Spectroscopy: Society for Applied Spectroscopy >Rapid, Noninvasive Quantitative Determination of Acyclovir in Pharmaceutical Solid Dosage Forms Through their Poly(vinyl chloride) Blister Package by Solid-State Fourier Transform Raman Spectroscopy
【24h】

Rapid, Noninvasive Quantitative Determination of Acyclovir in Pharmaceutical Solid Dosage Forms Through their Poly(vinyl chloride) Blister Package by Solid-State Fourier Transform Raman Spectroscopy

机译:固态傅里叶变换拉曼光谱通过聚氯乙烯泡罩包装快速,无创定量测定药物固体剂型中的阿昔洛韦

获取原文
获取原文并翻译 | 示例
           

摘要

Fourier transform (FT) Raman spectroscopy based on band intensity or band area measurements was used for the quantitative determination of acyclovir in pharmaceutical solid dosage forms through their poly(vinyl chloride) blister package. Univariate calibration using the bands observed at 1690, 1630, 1574, 1482, 1181, 578, and 508 cm~(-1) was found to be sufficient for the analysis. Calibration curves were linear, the correlation coefficients being 0.997-0.9993 and 0.996-0.9991 for band intensity and band area measurements, respectively. Results obtained compare well, as indicated by the t-test, with those obtained by the current United States Pharmacopoeia (USP 24) and National Formulary (NF 19) method. Precision ranged from 0.7-4.5 and 0.4-4.0% RSD (n=3) for band intensity and band area measurements, respectively. The developed nondestructive FT-Raman method is rapid, simple, and can be used for the on-line, real-time monitoring of acyclovir formulation production lines.
机译:基于谱带强度或谱带面积测量的傅里叶变换(FT)拉曼光谱用于通过其聚氯乙烯泡罩包装定量测定药物固体剂型中的阿昔洛韦。发现使用在1690、1630、1574、1482、1181、578和508 cm〜(-1)处观察到的谱带进行单变量校准足以进行分析。校准曲线是线性的,带强度和带面积测量的相关系数分别为0.997-0.9993和0.996-0.9991。如t检验所示,所得结果与通过当前美国药典(USP 24)和国家处方(NF 19)方法获得的结果进行了很好的比较。频段强度和频段面积测量的精度分别为0.7-4.5和0.4-4.0%RSD(n = 3)。所开发的无损FT-Raman方法快速,简单,可用于阿昔洛韦制剂生产线的在线实时监控。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号