Case Series of All-Arthroscopic Treatment for Terrible Triad of the Elbow: Indications and Clinical Outcomes

机译:All-Arthroscopic系列病例的治疗可怕的肘部的三和弦:迹象临床结果

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the results of all-arthroscopic treatment of the terrible triad of the elbow, a combination of elbow dislocation, radial head dislocation, and coronoid process fracture, and its complications. Methods: We performed a retrospective review of consecutive patients with terrible triad who underwent all-arthroscopic treatment between January 2011 and December 2016. All-arthroscopic treatment was performed in the unstable elbows after manual reduction. Clinical evaluation was performed at least 2 years postoperatively. Patients with another fracture in the upper extremity and previous fracture of the affected elbow were excluded. A radial head fracture that was stable enough to reduce or involved less than 25% of the articular surface for partial excision and Regan-Morrey classification type I and type II coronoid process fractures were treated arthroscopically. Range of motion, radiologic outcomes, surgical complications, and the Mayo Elbow Performance Score were evaluated at the final follow-up. The Mann-Whitney test was used for statistical analysis. Results: A total of 24 patients met the inclusion criteria, and the average age was 47.6 years. Coronoid process fractures were fixed in all patients, by use of Kirschner wires in 15 (62.5%) and pullout sutures in 9 (37.5%). Radial head fractures were treated using screw or K-wire fixation in 4 patients (16.7%); only the fragment of the fracture was resected in 11 patients (45.8%). In all 24 cases (100%), the lateral collateral ligaments were repaired. At the final follow-up, the mean flexion contracture angle was 4.8 degrees +/- 1.1 degrees and the mean flexion angle was 132.5 degrees +/- 6.3 degrees. Clinical scores were satisfactory, with a mean Mayo Elbow Performance Score of 93 points. However, nonunion of coronoid fractures was observed in 4 patients (16.7%). There was 1 case of pin-site irritation. Conclusions: All-arthroscopic treatment for the terrible triad can provide an excellent safety profile without the need for a large incision if the indications are met.
机译:目的:评估的结果all-arthroscopic治疗可怕的三和弦肘,肘部脱位的组合,径向头错位,喙突骨折,其并发症。连续进行了回顾性研究可怕的三元组患者接受2011年1月之间all-arthroscopic治疗2016年12月。执行后的不稳定的肘部手册减少。术后2年以上。另一个裂缝在上肢和以前骨折受影响的肘部排除在外。足以减少或涉及的不到25%对部分切除和关节面Regan-Morrey分类I型和II型冠突骨折治疗arthroscopically。结果,手术并发症和梅奥肘性能评分进行评估最后的随访。进行统计分析。病人满足入选标准,平均年龄是47.6岁。骨折固定在所有的病人,使用柯式电线在15(62.5%)和撤军缝合线在9(37.5%)。4例患者出现使用螺钉或钢丝固定(16.7%);切除11例(45.8%)。抵押品(100%)、外侧韧带修好了。屈曲挛缩角是1.1 + / - 4.8度度和弯曲角的平均值为132.5度+ / - 6.3度。满意的,意思是梅奥肘部性能得分93分。观察骨折4例(16.7%)。有1例pin-site过敏。结论:All-arthroscopic治疗可怕的三元组可以提供一个优秀的安全配置文件不需要大切口的迹象。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号