Optimization of Measurement Conditions of an Energy Dispersive X-ray Fluorescence Spectrometer with High-Energy Polarized Beam Excitation for Analysis of Aerosol Filters

机译:气溶胶滤光片分析用高能偏振光束激发能色散X射线荧光光谱仪的测量条件的优化

获取原文
获取原文并翻译 | 示例
           

摘要

A new commercial energy dispersive X-ray fluorescence spectrometer (EDXRF), applying a three-dimensional geometry and highenergy excitation, was optimized for the quantitative analysis of aerosols deposited on filters. The preliminary results are presented here. First-order calibration curves were obtained for 20 elements deposited on the filters. The accuracy of the applied method and of the obtained calibration curves was checked by the measurement of a standard reference material from NIST. The precision of the analysis for the majority of the analytes was better than 10percent. Due to the obtained low detection limits, it is possible to determine the analytes usually present at very low concentrations in ambient air, such as, e.g., Cd, Sb, Cr, and V. It is also possible to decrease significantly the time of analysis or the time of the sampling.
机译:应用了三维几何形状和高能激发的新型商业能量色散X射线荧光光谱仪(EDXRF),可以对沉积在过滤器上的气溶胶进行定量分析。初步结果显示在这里。获得了沉积在滤波器上的20个元素的一阶校准曲线。通过测量来自NIST的标准参考物质来检查所应用方法和所获得校准曲线的准确性。大多数分析物的分析精度均优于10%。由于获得的低检测限,有可能确定通常以非常低的浓度存在于环境空气中的分析物,例如Cd,Sb,Cr和V。还可以大大减少分析时间或采样时间。