...
首页> 外文期刊>The journal of hand surgery Asian-Pacific volume. >Effectiveness and Safety in Closed Mini-Transverse Incision with Hydro-Dissection Technique in Carpal Tunnel Release: A Cadaveric Study
【24h】

Effectiveness and Safety in Closed Mini-Transverse Incision with Hydro-Dissection Technique in Carpal Tunnel Release: A Cadaveric Study

机译:有效性和安全性在Mini-Transverse关闭切口Hydro-Dissection技术腕管释放:尸体的研究

获取原文
获取原文并翻译 | 示例

摘要

Background: Closed mini-wrist transverse incision for carpal tunnel release has been reported in decreasing surgical scar problems, but there were few cadaveric studies that proved the effectiveness and safety in this technique without protective instrument to the median nerve. Hydro-dissection was previously showed to separate median nerve and deep structures during percutaneous ultrasound guided transverse carpal ligament release. This cadaveric study aims to demonstrated effectiveness and safety of closed transverse carpal ligament (TCL) release though the mini-transverse incision at distal wrist crease combined with hydrodissection technique. Neither special instrument nor retractor was used to protect neurovascular structures.Methods: Twelve fresh frozen cadaveric wrists were included in this study. Completeness of TCL release and injury to the adjacent neurovascular structures were assessed by direct visualization. Thickness of TCL, TCL length and distance from incision to adjacent neurovascular structures were also recorded.Results: Complete release of TCL was demonstrated in all 12 (100%) wrists underwent the mini-transverse incision TCL release at distal wrist crease and hydro-dissection technique. No injury to the adjacent neurovascular structures was found in all 12 wrists. Mean of thickness of TCL and TCL length were 3 mm and 28.7 mm, respectively. The ulnar artery was the nearest structure to the incision (mean = 3.7 mm).Conclusions: The closed mini-transverse incision TCL release at distal wrist crease with hydro-dissection technique demonstrated completeness of TCL division and safety to the neurovascular structures without protecting retractor or special instrument.
机译:背景:mini-wrist横向切口关闭对腕管释放已经被报道减少手术疤痕问题,但也有一些尸体的研究,证明了该技术的有效性和安全性没有防护工具中值神经。单独的正中神经和深层结构经皮超声引导横向腕韧带释放。证明了有效性和安全性的关闭腕横韧带(TCL)释放在远端手腕mini-transverse切口折痕结合技术囊袋上。使用了特殊的仪器和牵开器保护神经与血管的结构。十二个新鲜冷冻尸体的手腕纳入本研究。释放和邻近的神经与血管的损伤结构被直接可视化评估。TCL的厚度,TCL长度和距离切口邻近神经与血管的结构也被记录下来。TCL在所有12(100%)手腕经历了mini-transverse切口TCL在远端手腕折痕和释放hydro-dissection技术。相邻的神经与血管的结构中被发现所有12手腕。分别是3毫米和28.7毫米,长度。尺动脉是最近的结构切口(意味着= 3.7毫米)。在远端mini-transverse切口TCL释放手腕折痕与hydro-dissection技术展示了TCL分裂和完整性没有安全的神经与血管的结构保护牵开器或特殊工具。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号