...
首页> 外文期刊>Applied Spectroscopy: Society for Applied Spectroscopy >Attenuated Total Reflection Infrared Spectroscopy: An Efficient Technique to Quantitatively Determine the Orientation and Conformation of Proteins in Single Silk Fibers
【24h】

Attenuated Total Reflection Infrared Spectroscopy: An Efficient Technique to Quantitatively Determine the Orientation and Conformation of Proteins in Single Silk Fibers

机译:衰减全反射红外光谱:一种定量确定单丝纤维中蛋白质取向和构象的有效技术

获取原文
获取原文并翻译 | 示例

摘要

Polarized attenuated total reflection (ATR) infrared spectroscopy is an efficient technique to determine the orientation and conformation of a large variety of samples, but it is more difficult to apply to very small specimens such as silk fibers. The Golden Gate single-reflection ATR accessory that uses diamond as an ATR element and a focalized beam turns out to be highly efficient to study quantitatively the orientation and conformation of a single silk fibroin filament of the silkworm Bombyx mori that is about 10 (mu)m in diameter. For orientation measurements, rotating the sample instead of the electric field greatly simplifies the theoretical analysis and keeps the penetration depth of the infrared radiation constant. A sample holder that can be fitted on the ATR accessory has thus been developed to allow accurate rotation of the sample and to obtain spectra with a low, non-damaging, and reproducible pressure on the fiber. To validate the method, spectra have been recorded as a function of the angle theta between the fiber axis and the polarization of the incident radiation. The data have been fitted following the cosine square dependency of the absorbance with respect to the angle theta. The procedure has been applied to the spectral components of the amide I bands, as determined from spectral decomposition. Multiple angle measurements turn out to be quite useful to correct systematic angle errors and validate the accuracy of the curve-fitting parameters of the band decomposition. By using the calculated dichroic ratio, a parameter of -0.46 +- 0.01 has been calculated for the antiparallel beta-sheets and -0.04 +- 0.02 for the remaining structures. From the orientation-insensitive spectrum A_(0), the amount of beta-sheets has been estimated to 49 +- 3percent. The results obtained from only two measurements with the electric field of the incident radiation parallel and perpendicular to the fiber axis has demonstrated that ATR spectroscopy can be used routinely in quantitative studies of the molecular orientation and conformation of macromolecules.
机译:偏振衰减全反射(ATR)红外光谱法是一种有效的技术,可确定各种样品的方向和构象,但要应用于非常小的样品(如丝纤维)则更加困难。事实证明,使用钻石作为ATR元素和聚焦光束的Golden Gate单反射ATR附件非常有效地定量研究了蚕Bombyx mori的单丝素蛋白丝的方向和构象,该单丝的蛋白丝约10(μ)直径m。对于方向测量,旋转样品而不是电场可以大大简化理论分析,并使红外辐射的穿透深度保持恒定。因此,已经开发出了一种可以安装在ATR附件上的样品架,可以精确地旋转样品并获得具有低,无损且可再现的光纤压力的光谱。为了验证该方法,已将光谱记录为纤维轴与入射辐射的偏振之间的角度theta的函数。根据吸光度相对于角度θ的余弦平方依赖性来拟合数据。该方法已应用于由光谱分解确定的酰胺I谱带的光谱成分。事实证明,多角度测量对于纠正系统角度误差和验证谱带分解的曲线拟合参数的准确性非常有用。通过使用计算出的二向色比,反平行β片层的参数为-0.46 +-0.01,其余结构的参数为-0.04 +-0.02。根据对方向不敏感的光谱A_(0),β-折叠的数量估计为49±3%。通过仅两次测量入射辐射的电场平行于和垂直于纤维轴的电场而获得的结果表明,ATR光谱学可以常规用于定量研究大分子的分子取向和构象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号