Feasibility of in vivo thyroid I-131 monitoring with an imaging plate

机译:用成像板进行体内甲状腺I-131监测的可行性

获取原文
获取原文并翻译 | 示例

摘要

A new in vivo thyroid I-131 monitoring method was devised by using an imaging plate (IP). A thyroid image obtained with a realistic neck-thyroid phantom showed a unique shape characteristic of the thyroid gland. A I-131 thyroid imaging allows visual confirmation of thyroid accumulation of I-131. The detection limit of the IP system of 290 Bq was about 1/100 of the screening level of 30 kBq in cases of public emergencies. The IP system is applicable for thyroid I-131 monitoring. (C) 2001 Elsevier Science Ltd. All rights reserved. [References: 16]