Determination of X- and gamma-ray emission intensities in the decay of I-131

机译:确定I-131衰减时的X射线和伽马射线发射强度

获取原文
获取原文并翻译 | 示例

摘要

The activity per unit mass of an iodine-131 solution was absolutely standardized by both the 4 pi beta-gamma coincidence method and the 4 pi gamma counting technique. The calibrated solution was used to prepare point sources after a preliminary deposit of AgNO3 to prevent the loss of volatile iodine. Relative and absolute photon emission intensities of 15 sgamma-rays and those of the two K X-rays of xenon were determined by gamma-ray spectrometry, with relative uncertainties of 0.8% for the three main emissions. (C) 2015 Elsevier Ltd. All rights reserved.
机译:碘131溶液的单位质量活性通过4 pi beta-gamma巧合方法和4 pi gamma计数技术都得到了绝对标准化。预先沉积AgNO3后,使用校准溶液制备点源,以防止挥发性碘流失。 γ射线光谱法测定了15 sγ射线和氙的两个K X射线的相对和绝对光子发射强度,三个主要发射的相对不确定度为0.8%。 (C)2015 Elsevier Ltd.保留所有权利。