Purpose: The aim was to study the link between refractive error and corneal biomechanical properties. Methods: Corneal hysteresis and corneal resistance factor were measured using the Ocular Response Analyser in 117 participants. The spherical equivalent refractive error of the participants ranged between -9.00 and +3.00D. Results: Corneal hysteresis and corneal resistance factor showed a considerable degree of variability between individuals. Corneal hysteresis was not found to correlate significantly with refractive error (p = 0.82). Corneal resistance factor showed a weak but significant correlation with spherical equivalent refractive error (r 2= 0.04; p = 0.03), with myopic participants exhibiting a higher corneal resistance factor compared with non-myopes. Conclusions: Refractive error accounted for four per cent of the variance in corneal resistance factor measurements, indicating that patients with mild to moderate myopia have higher corneal resistance compared with non-myopes.
机译:目的:目的是研究之间的联系屈光不正,角膜生物力学属性。角膜阻力系数测量使用117年眼响应分析器的参与者。球形的屈光不正参与者介于-9.00和3.00 + d之间。结果:角膜滞后和角膜表现出相当程度的阻力因素个体之间的差异。磁滞不存在关联与屈光不正显著(p = 0.82)。角膜阻力系数显示弱,但球形对等词的显著相关屈光不正(r 2 = 0.04;近视的参与者表现出更高的角膜阻力系数与non-myopes相比。结论:屈光不正占了四个方差的每分钱角膜阻力因子的测量,表明病人轻度至中度近视有更高的角膜阻力与non-myopes相比。