首页> 外文期刊>Clinical & experimental optometry: journal of the Australian Optometrical Association >Application of optical coherence tomography in glaucoma suspect eyes
【24h】

Application of optical coherence tomography in glaucoma suspect eyes

机译:应用光学相干断层扫描青光眼怀疑的眼睛

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The aim of the study was to compare the optical coherence tomography (OCT) parameters of the optic nerve head (ONH) and retinal nerve fibre layer (RNFL) and to identify which measurements are best able to differentiate between normal and glaucoma suspect eyes. Methods: The study included 27 eyes with ocular hypertension (OHT), 33 eyes with pre-perimetric glaucoma (PG), 30 perimetrically unaffected eyes of patients with glaucoma in the fellow eye (FE) and 58 eyes of age-matched normal volunteers. All subjects underwent a complete eye examination with standard automated perimetry, optic disc photography and OCT imaging. Peripapillary 'fast RNFL thickness scans' and 'fast optic disc scans' were performed with time-domain OCT. The ONH and RNFL parameters were compared among the four study groups. The ONH and RNFL parameters were examined alone and then combined via four linear discriminant functions (LDF): LDF 1, the optimal combination of ONH parameters; LDF 2, the optimal combination of RNFL parameters; LDF 3, the optimal combination of both ONH and RNFL parameters; and LDF 4, the optimal combination of the best 11 parameters. The areas under the receiver operating curves (AUC) and the sensitivity at fixed specificity of at least 80 and 95 per cent were calculated for single parameters and LDF combinations and then compared. The best 11 parameters were selected based on their AUC values. Results: Comparative analysis of OCT parameters revealed statistically significant differences in all seven ONH parameters in both PG and FE groups (and only in one ONH measurement in the ocular hypertensive group) when compared with normal eyes. Most of the RNFL parameters demonstrated statistically significant differences in all of the study groups when compared with the control group. The max-min parameter (0.835), inferior quadrant (0.833) and average RNFL thickness (0.829) obtained the highest AUC values in the whole glaucoma suspect group. The rim area had the best diagnostic accuracy among the ONH parameters (AUC = 0.817). The AUC values of the four LDF were: 0.825 (LDF 1), 0.882 (LDF 2), 0.902 (LDF 3) and 0.888 (LDF 4). Statistically significant differences were found between the AUC values of the single best ONH and RNFL parameters and LDF 3 and LDF 4. Conclusions: In the present study, RNFL parameters presented with better discriminatory abilities than ONH parameters in the OHT and FE groups. The ONH parameters demonstrated better diagnostic precision in differentiating between PG and normal eyes. The average RNFL thickness, max-min parameter and inferior quadrant RNFL thickness had the best abilities among single OCT measurements for discriminating between glaucoma suspect (including all ocular hypertensive, PG and FE eyes) and normal eyes. The combination of RNFL parameters only or both ONH and RNFL parameters, using linear discriminant analysis, provided the best classification results, improving the diagnostic accuracy of the instrument.
机译:目的:这项研究的目的是比较光学相干断层扫描(OCT)的参数视神经头(“)和视网膜神经纤维层(RNFL)和识别它测量是最能区分正常和青光眼之间怀疑的眼睛。方法:研究包括27个眼睛和眼高血压(OHT),与pre-perimetric 33的眼睛青光眼(PG)、30 perimetrically影响眼睛的青光眼患者的眼(铁)和58眼睛的同龄正常志愿者。受试者接受一个完整的眼科检查与标准自动视野测量,视神经盘摄影和10月成像。RNFL厚度扫描”和“快速视神经盘扫描”进行时域10月“和在四个相比RNFL参数学习小组。检查,然后通过四个线性组合法律辩护基金法律辩护基金判别函数():1,最优结合“参数;结合RNFL参数;“和RNFL最佳组合参数;最好的11个参数。操作曲线(AUC)和接收器至少80的敏感性以固定特异性对单一和95%计算法律辩护基金参数和组合比较。根据他们的AUC值。10月参数显示统计分析在所有七个“显著差异参数在PG和铁组(只在一个“眼压的测量集团)与正常相比的眼睛。RNFL参数统计在所有研究的显著差异组与对照组相比。不等式性质参数(0.835),劣质象限(0.833)和平均RNFL厚度(0.829)获得最高的AUC值青光眼的怀疑。在“参数(AUC诊断的准确性= 0.817)。法律辩护基金法律辩护基金0.825(1),0.882(2),0.902法律辩护基金(3)和法律辩护基金0.888(4),具有统计学意义的AUC值之间的差异被发现最好的“法律辩护基金和RNFL参数和3法律辩护基金和4。RNFL参数提供更好歧视性的能力比“参数OHT和铁组。了更好的诊断精度区分PG和正常的眼睛。和RNFL厚度、平均不等式性质参数劣质象限RNFL厚度有最好的在单一OCT测量能力青光眼怀疑之间的歧视(包括所有的眼压、PG和铁眼)和正常的眼睛。参数只或“和RNFL参数,使用线性判别分析,提供了最好的分类结果,改善诊断仪器的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号