Comparative study of Acrysof ReSTOR multifocal intraocular lenses +4.00 D and +3.00 D: Visual performance and wavefront error

机译:比较研究的Acrysof备份文件夹多焦点的眼内晶状体+ 4.00 D和+ 3.00 D:视觉性能和波前误差

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The aim was to evaluate visual performance and wavefront error after implantation of three models of Acrysof ReSTOR multifocal intraocular lenses (MIOLs). Methods: This prospective comparative six-month study comprised 60 eyes having phacoemulsification and implantation of three diffractive AcrySof ReSTOR MIOLs: SN60D3 +4.00 D spherical MIOL (group 1), SN6AD3 +4.00 D aspheric MIOL (group 2) and SN6AD1 +3.00 D aspheric MIOL (group 3). Results: The distance visual acuity was at least 0.1 logMAR in 88.8 per cent of group 1, 88.8 per cent of group 2 and 87.5 per cent of group 3. The distance-corrected near vision was 0.02 ± 0.04 logMAR in group 1, 0.02 ± 0.05 logMAR in group 2 and 0.01 ± 0.03 logMAR in group 3 (p = 0.822). The distance-corrected intermediate vision was 0.26 ± 0.07, 0.22 ± 0.09 and 0.04 ± 0.05, respectively (p < 0.001). The root-mean-square (RMS) of ocular spherical aberration was significantly lower in groups 2 and 3 compared to group 1 (p = 0.048). Conclusion: All diffractive MIOLs provided good vision for far and near. ReSTOR MIOL +3.00 also restored intermediate vision. Aspheric MIOLs +4.00 and +3.00 induced significantly lower spherical aberration compared to spherical MIOL +4.00.
机译:背景:目的是评估视觉性能和波前误差植入的三个模型Acrysof备份文件夹多病灶的人工晶体(MIOLs)。这个前瞻性比较6个月的研究由60眼睛乳化植入三个衍射AcrySof备份文件夹MIOLs: SN60D3 + 4.00 D球形MIOL(组1),SN6AD3 + 4.00 D非球面MIOL SN6AD1(组2)+ 3.00 D非球面MIOL(组3)。结果:距离视力至少0.1 logMAR组1的88.8%,88.8%的集团2和3组的87.5%。distance-corrected附近视力为0.02±0.04logMAR组1、组2中0.02±0.05 logMAR和0.01±0.03 logMAR 3组(p = 0.822)。distance-corrected中间视觉0.26±0.07,0.22±0.09,0.04±0.05,(分别p < 0.001)。(RMS)眼部的球面像差显著降低相比,组2和3第1组(p = 0.048)。MIOLs远近提供了良好的视野。备份文件夹MIOL + 3.00还恢复中间愿景。相比显著降低球面像差球形MIOL + 4.00。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号