首页> 外文期刊>Vox Sanguinis: International Journal of Blood Transfusion and Immunohaematology >Survival and recovery of apheresis platelets stored in a polyolefin container with high oxygen permeability.
【24h】

Survival and recovery of apheresis platelets stored in a polyolefin container with high oxygen permeability.

机译:apheresis血小板生存和复苏存储在聚烯烃与高氧容器渗透率。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND OBJECTIVES: Oxygen permeability is important in platelet storage media. We compared a new polyolefin container with enhanced oxygen permeability (PO-80; Kawasumi, Tokyo, Japan) to a widely used alternative (PL2410; Baxter Healthcare, Deerfield, IL, USA). MATERIALS AND METHODS: In vitro characteristics of paired platelet concentrates (PCs; mean 4.2 x 10(11)/250 ml plasma/bag) stored in PO-80 or PL2410 were assessed through 9 days of storage. In vivo recovery and survival of 7-day-old autologous PCs were assessed according to the Murphy method. RESULTS: Laboratory assessment of platelet quality favoured PO-80 during 9 days of storage with statistically significant differences in glucose consumption (2.75 vs. 4.93 mmol/10(12)/24 h in the interval 120-168 h), lactate generation (4.37 vs. 8.11 mmol/10(12)/24 h in the interval 120-168 h), pressure of oxygen (pO(2)) (59.3 vs. 38.1 mmHg at day 1), and HCO(3)(-) (14.7 vs. 13.4 mmol/l at day 1). Statistically significant differences were not seen in aggregation, hypotonic shock response or pH. In vivo assessment of autologous platelets stored 7 days in the PO-80 container revealed that recovery was 82.1% and survival was 81.0% of fresh control. Seven-day stored PCs in PO-80 were shown in vivo to be non-inferior to fresh platelets, with upper confidence limits (UCL(95)) in recovery and survival of stored PCs below the maximum acceptable difference (MAD); 15.3% UCL(95) < 20.4% MAD and 2.1 days UCL(95) < 2.1 days MAD. CONCLUSIONS: The in vitro characteristics of PCs stored in a highly oxygen-permeable container were stable at least 7 days. The in vivo study supports the suitability of PO-80 for 7-day platelet storage.
机译:背景和目的:氧气渗透重要的血小板存储媒体。一个新的聚烯烃容器与增强氧气渗透率(po - 80;广泛使用的替代(PL2410;美国医疗保健、迪尔菲尔德,IL)。方法:体外配对的特征血小板浓缩液(电脑;毫升血浆/袋)存储在po - 80或PL2410评估通过9天的存储。恢复和生存7-day-old自体pc根据墨菲的方法进行评估。结果:实验室评估血小板质量青睐po - 80在9天的存储在统计上有显著差异葡萄糖消耗(2.75 vs 4.93更易10 (12)/ 24h在区间120 - 168 h),乳酸生成(4.37 vs 8.11更易10(12)/ 24小时的时间间隔120 - 168 h),压力的氧气(pO) (2) (59.3 vs。在第一天38.1毫米汞柱),和HCO(3)(-)(14.7和13.4在第一天更易/ l),具有统计学意义差异未见的聚合,低渗的冲击响应或博士体内评估自体血小板保存7天在po - 80容器显示复苏82.1%,存活率是81.0%新鲜的控制。七天的电脑存储在po - 80所示非劣到新鲜血小板,上层置信区间(UCL(95))的恢复存储电脑下面最大的生存可接受的差异(疯了);伦敦大学学院(95)< 20.4%的疯狂和2.1天2.1天疯了。结论:体外pc的特点存储在一个高度富氧容器稳定至少7天。支持7天的po - 80的适用性血小板存储。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号