首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Control and energy simulation of variable refrigerant flow air conditioning system combined with outdoor air processing unit
【24h】

Control and energy simulation of variable refrigerant flow air conditioning system combined with outdoor air processing unit

机译:结合室外空气处理机组的可变制冷剂流量空调系统的控制与能量模拟

获取原文
获取原文并翻译 | 示例
           

摘要

A variable refrigerant flow (VRF) unit and outdoor air (OA) processing unit combined air conditioning system is proposed as a solution for ventilation problems in VRF systems. System structure and control strategies are addressed. Simulation platform is established based on component and sub-system models developed. Control and energy performances analysis are then put forward under various conditions. It is found that the combined system could maintain all the zones at their specific set-points within small errors no matter set-points of the zones are the same or different. In addition, indoor air quality can be ensured. Energy efficiency characteristics of the combined system are greatly affected by the OA supply temperature of the OA processing unit, which opens up the opportunity of minimizing the energy consumption of the combined system through optimal control strategy. Results reveal that the best OA supply temperature can be obtained through optimizing part load ratio of the OA processing unit to a range in which the system operates with high efficiency.
机译:提出了一种可变制冷剂流量(VRF)单元和室外空气(OA)处理单元组合空调系统,以解决VRF系统中的通风问题。解决了系统结构和控制策略。基于开发的组件和子系统模型建立仿真平台。然后提出了在各种条件下的控制和能效分析。已经发现,无论区域的设定点相同还是不同,组合系统都可以将所有区域保持在特定的设定点以内,误差很小。另外,可以确保室内空气质量。 OA处理单元的OA供给温度极大地影响了组合系统的能效特性,这为通过最佳控制策略将组合系统的能耗降至最低提供了机会。结果表明,通过将OA处理单元的部分负载比优化到系统高效运行的范围,可以获得最佳的OA供应温度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号