In this study the performance of defrost systems applied to household refrigerators was experimentally evaluated through a purpose-built testing apparatus. The test bench is comprised of a calorimeter, a refrigerated cabinet and a humidifying system. Three distinct types of electrical heaters (distributed, calrod and glass tube) and three actuation modes (integral power, power steps and pulsating power) were investigated. The experiments were carried out under controlled conditions in order to ensure the same frost accumulation pattern over the evaporator. It was found that the defrost efficiency of the three types of heaters is practically the same for each operating mode. The highest efficiency of approximately 48% was obtained with the glass tube heater operating in power steps. However, this heater reached the highest temperature levels. The calrod heater seems to be the most appropriate not only because of its efficiency, which is compatible with the other options, but also due to its low cost and easy installation. However, standardized energy consumption tests need to be carried out before this finding can be generalized.
机译:在这项研究中,通过专用测试设备对用于家用冰箱的除霜系统的性能进行了实验评估。测试台由热量计,冷藏柜和加湿系统组成。研究了三种不同类型的电加热器(分布式,电热管和玻璃管)和三种致动模式(积分功率,功率阶跃和脉动功率)。为了确保蒸发器上的霜积聚模式相同,在受控条件下进行了实验。已经发现,对于每种操作模式,三种类型的加热器的除霜效率实际上是相同的。玻璃管加热器以功率步进运行时,可获得约48%的最高效率。但是,该加热器达到了最高温度水平。 Calrod加热器似乎是最合适的,这不仅是因为其效率与其他选件兼容,而且还因为其成本低廉且易于安装。但是,在将这一发现推广之前,需要进行标准化的能耗测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号