首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Performance evaluations of air-cooled condensers using pure and mixture refrigerants by four-section lumped modelling methods
【24h】

Performance evaluations of air-cooled condensers using pure and mixture refrigerants by four-section lumped modelling methods

机译:通过四部分集总建模方法评估使用纯制冷剂和混合制冷剂的风冷冷凝器的性能

获取原文
获取原文并翻译 | 示例

摘要

A simulation model for air-cooled finned-tube condensers is constructed utilising the modified lumped method. Within the model the condenser is divided into four sections, a superheated section, two two-phase regions, and subcooled section. The classification of the two-phase region is based on the experimental results of the heat transfer behaviour during refrigerant inside pipe condensation. The proposed model is validated with test data and used to compare the performances of differently structured condensers using refrigerants R22 and R404A. Some instructions of how to use the model in designing and developing various condenser arrangements are proposed.
机译:利用改进的集总法建立了风冷翅片管冷凝器的仿真模型。在模型中,冷凝器分为四个部分:过热部分,两个两相区域和过冷部分。两相区域的分类是基于制冷剂在管道内冷凝时的传热行为的实验结果。所提出的模型已通过测试数据验证,并用于比较使用制冷剂R22和R404A的不同结构的冷凝器的性能。提出了一些在设计和开发各种冷凝器装置时如何使用该模型的说明。