首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Thermal performance of a 10-kW phase-change plate heat exchanger with metal foam filled channels
【24h】

Thermal performance of a 10-kW phase-change plate heat exchanger with metal foam filled channels

机译:带金属泡沫填充通道的10 kW相变板式换热器的热性能

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Compact-sized organic Rankine cycle (ORC) power generators call for small-scale heat exchangers to work with them. Since the heat transfer area plays a direct role in the performance of heat exchangers, micro cellular structures such as metal foams are proposed to increase the heat duty of heat exchangers by increasing the surface area while maintaining their small size. In this experimental study, the performance of a 10-kW heat exchanger with channels filled with copper metal foam was investigated. A hot water loop was designed for heat input. The cold side of the heat exchanger works with R245fa as the working fluid. Single-phase and two-phase experiments were performed with different mass fluxes ranging from 180 to 600 kg/m(2)s. The effect of the pores per inch (PPI), working pressure, and different arrangements of metal foams was also investigated. Although the metal foam increases the pressure drop in the channel, it increases the recovered waste heat from the heat source and overall heat transfer coefficient of the heat exchanger by up to 2.3 times compared to a conventional heat exchanger without metal foams. (C) 2016 Elsevier Ltd. All rights reserved.
机译:紧凑型有机朗肯循环(ORC)发电机要求小型热交换器与它们一起工作。由于传热面积在热交换器的性能中起着直接作用,因此提出了微孔结构,例如金属泡沫,以通过增加表面积同时保持其小尺寸来增加热交换器的热负荷。在此实验研究中,研究了带有装满铜泡沫金属的通道的10 kW热交换器的性能。热水回路设计用于热量输入。热交换器的冷侧与R245fa一起用作工作流体。单相和两相实验的质量通量范围为180至600 kg / m(2)s。还研究了每英寸孔数(PPI),工作压力和金属泡沫的不同排列的影响。尽管金属泡沫增加了通道中的压降,但与没有金属泡沫的传统热交换器相比,它使从热源回收的废热和热交换器的总传热系数增加了多达2.3倍。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号