首页> 外文期刊>Aquaculture International >Biofloc management with different flow rates for solids removal in the Litopenaeus vannamei BFT culture system
【24h】

Biofloc management with different flow rates for solids removal in the Litopenaeus vannamei BFT culture system

机译:南美白对虾BFT培养系统中不同流速的生物絮凝物去除固体

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Different water flows for solids removal in the Litopenaeus vannamei BFT system were evaluated. One control (no solids removal) and two treatments using different water flows, high (3945 L h(-1)-HF) and low (1750 L h(-1)-LF), were used with no water replenishment after each process, and the total dry weight of the solids was measured. L. vannamei (0.18 +/- 0.06 g; 350 individuals m(-2)) were stocked in 35-m(-3) tanks. For 17 weeks, the physical and chemical parameters were maintained within the recommended. To keep the total suspended solids concentrations at approximately 500-600 mg L-1, clarifying was performed. The average water volume flowed by clarifiers was significantly different (p 0.05) between HF (205 +/- 34 m(3)) and LF (114 +/- 24 m(3)). There was a significant decrease (p 0.05) in the final tank volume in HF (28.09 +/- 0.92 m(3)) and LF (28.62 +/- 1.38 m(3)) due to the clarifying. Before clarifying (initial sample) and at the end of experiment (final sample) were not significantly different (p > 0.05) for crude protein, moisture or ash. The crude lipid of the LF in the final period was significantly lower (p 0.05) compared to others in both periods. The survival, productivity and food conversion ratio were significantly better (p 0.05) in the HF and LF treatments compared to those of the control. The best shrimp performance was obtained with solids removal. The lower flow in the clarifier facilitated particle settling, allowing adjustment of the flow.
机译:评估了南美白对虾BFT系统中用于去除固体的不同水流量。使用一个对照(无固体去除)和使用不同水流量的两种处理方法(高(3945 L h(-1)-HF)和低(1750 L h(-1)-LF)),每个过程后均不补充水,并测量固体的总干重。将南美白对虾(0.18 +/- 0.06 g; 350个个体m(-2))放入35-m(-3)的水箱中。在17周内,理化参数保持在推荐范围内。为了使总悬浮固体浓度保持在约500-600 mg L-1,进行了澄清。澄清池流过的平均水量在HF(205 +/- 34 m(3))和LF(114 +/- 24 m(3))之间有显着差异(p <0.05)。由于澄清,最终罐容积在HF(28.09 +/- 0.92 m(3))和LF(28.62 +/- 1.38 m(3))中显着减小(p <0.05)。澄清前(初始样品)和实验结束时(最终样品)的粗蛋白,水分或灰分无显着差异(p> 0.05)。与两个时期相比,最后时期的LF的粗脂质显着降低(p <0.05)。与对照组相比,HF和LF处理的存活率,生产力和食物转化率显着更好(p <0.05)。去除固体后,虾的性能最佳。澄清池中较低的流量有助于颗粒沉降,从而可以调节流量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号