In this paper, time-dependent changes in the energy and exergy performance of the Gonen geothermal district heating system (GDHS) due to seasonal differences in the energy requirement of the system are investigated. In this extend, over a one-year period the system is monitored by using fixed and portable measuring devices and all the data needed for the calculations are collected. Energy and exergy analysis of the system and its main components is carried out for winter, summer and transition seasons separately, considering the seasonal changes in the heating load of the system. The highest energy and exergy efficiencies of the overall Gonen GDHS are determined to be 45.78% and 50.45% in the transition seasons, respectively, while the lowest energy and exergy efficiencies are found to be 31.72% and 39.34% in the winter season, respectively. Besides, the annual average energy and exergy efficiencies are determined to be 41.07% and 45.86%, respectively.
机译:本文研究了由于系统能量需求的季节性差异而导致的Gonen地热集中供热系统(GDHS)的能量和火用性能随时间的变化。在此范围内,在一年的时间内,使用固定和便携式测量设备对系统进行监视,并收集了计算所需的所有数据。考虑到系统加热负荷的季节性变化,分别在冬季,夏季和过渡季节对系统及其主要组件进行能量和火用分析。整个Gonen GDHS在过渡季节的最高能量和火用效率分别确定为45.78%和50.45%,而在冬季,最低的能量和火用效率分别为31.72%和39.34%。此外,确定年均能效和火用效率分别为41.07%和45.86%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号