The aim of the study is to select working fluids which have excellent performance and are environment friendly for moderately high temperature heat pump. Theoretical study is executed on several HCFCs and HFCs, with ODP of zero or small value firstly. And then research is carried out on a water-to-water vapor compression heat pump system applying the experimental assessment method of specifying working fluid parameters. Based on theoretical analysis, HFC245fa, HC600, HC600a, and a zeotropic refrigerant mixture HC600/HFC245fa (mass fraction: 2.83%/97.17%) are used as refrigerant for the experiment, with the evaporating temperature range of 30-55℃, and condensing temperature range of 60-100℃. Theoretical analysis shows that HCFC141b, HCFC123, HFC245ca, HC600 and HFC245fa have large COP_h. However, pressure ratio of HFC245ca, HCFC141b and HCFC123 is too large. The experimental results indicate that both the natural working fluids have excellent cycle performances in moderately high temperature heat pump cycle. Their heating coefficients of performance (COP_h) have little difference in the conditions of lower temperature cycle, but the cycle performance of HC600 is better than HC600a in higher temperature conditions. When the evaporating temperature and the condensing temperature are 44℃ and 90℃, COP_h of HC600 and HC600a are 3.84 and 3.33 respectively. In higher temperature conditions, the performance of the zeotropic refrigerant mixture HC600/HFC245fa is much better than HFC245fa. When the evaporating temperature is 50℃, and the cycle temperature lift is 45℃, COP_hs of HC600/HFC245fa are 3.74 and 3.83 respectively.
机译:该研究的目的是选择性能优异且对中等高温热泵环境友好的工作流体。对几种氟氯烃和氢氟碳化合物进行了理论研究,其ODP首先为零或小值。然后,采用指定工作流体参数的实验评估方法,对水-水蒸气压缩热泵系统进行了研究。根据理论分析,使用HFC245fa,HC600,HC600a和共沸混合制冷剂HC600 / HFC245fa(质量分数:2.83%/ 97.17%)作为实验制冷剂,蒸发温度范围为30-55℃,并进行冷凝。温度范围60-100℃。理论分析表明,HCFC141b,HCFC123,HFC245ca,HC600和HFC245fa具有较大的COP_h。但是,HFC245ca,HCFC141b和HCFC123的压力比太大。实验结果表明,两种天然工作流体在中等高温热泵循环中均具有出色的循环性能。在较低温度循环条件下,它们的性能加热系数(COP_h)差异不大,但在较高温度条件下,HC600的循环性能优于HC600a。当蒸发温度和冷凝温度分别为44℃和90℃时,HC600和HC600a的COP_h分别为3.84和3.33。在较高温度条件下,共沸混合制冷剂HC600 / HFC245fa的性能要好于HFC245fa。当蒸发温度为50℃,循环温度升高为45℃时,HC600 / HFC245fa的COP_hs分别为3.74和3.83。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号