首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >Experimental study on debonding defects detection in thermal barrier coating structure using infrared lock-in thermographic technique
【24h】

Experimental study on debonding defects detection in thermal barrier coating structure using infrared lock-in thermographic technique

机译:红外锁定热成像技术检测热障涂层结构脱胶缺陷的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

The infrared lock-in thermographic (LT) technique was used to detect debonding defects in ZrO2 coated Ni-based super alloy GH4169 plates. The basic principle of infrared LT technique and the correlated extraction algorithm of thermal wave signal feature was described. Experiments were performed to investigate the influence of the light source output power, number of analysis periods and modulation frequency on the detection results. Results show that, for the given size range of sample defects, greater total phase contrast C-ph can be obtained while the light source output power is 1000 W, number of analysis periods is 4, and modulation frequency is 0.2 Hz, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
机译:红外锁定热成像(LT)技术用于检测ZrO2涂层的Ni基超级合金GH4169板中的剥离缺陷。描述了红外LT技术的基本原理和热波信号特征的相关提取算法。进行实验以研究光源输出功率,分析周期数和调制频率对检测结果的影响。结果表明,对于给定尺寸的样品缺陷,在光源输出功率为1000 W,分析周期为4,调制频率为0.2 Hz的情况下,可以获得更大的总相衬C-ph。 (C)2016 Elsevier Ltd.保留所有权利。