This paper presents the experimental measurements conducted during liquid and flow boiling heat transfer of R1234ze(E) and R1234yf in an asymmetrically heated rectangular plain channel. The tests were run by varying the refrigerant mass velocity from 50 to 200 kg m(-2) s(-1), the vapour quality from 0.2 to 1, and the heat flux between 50 and 100 kW m(-2), at a constant saturation temperature of 30 degrees C. The results show that the nucleate boiling dominates the phase change process; furthermore, R1234yf shows higher two-phase heat transfer coefficients as compared to R1234ze(E), at the same operating test conditions. The developed measurement technique also permitted to estimate the vapour quality at the onset of the dryout. Furthermore, the direct visual observation of the boiling process allowed for a description of the phase-change and thermal crisis phenomena, including a detailed analysis of the dewettingrewetting phenomenon. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本文介绍了在不对称加热的矩形平通道中R1234ze(E)和R1234yf的液体和流动沸腾传热过程中进行的实验测量。通过将制冷剂质量速度从50更改为200 kg m(-2)s(-1),将蒸汽质量从0.2更改为1,并将热通量更改为50至100 kW m(-2),进行测试。结果表明,恒定的饱和温度为30摄氏度。结果表明,核沸腾在相变过程中占主导地位。此外,在相同的工作测试条件下,与R1234ze(E)相比,R1234yf显示出更高的两相传热系数。先进的测量技术还可以估算出干燥开始时的蒸汽质量。此外,对沸腾过程的直接视觉观察可以描述相变和热危机现象,包括对脱湿润湿现象的详细分析。 (C)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号