Lighting impacts the behavior, growth, and reproduction of poultry. Artificial lighting is extensively used in raising commercial poultry. The objective of this project was to determine the reliability, illuminance, and power consumption of alternative low-wattage light bulbs under conditions typical in poultry housing. A lighting test apparatus was used in a poultry house to allow simultaneous accelerated durability testing of up to four replications of three lamp types [one type of incandescent lamp, two different types of compact fluorescent lamps (CFLA and B), and one type of light emitting diode lamp (LED)]. Lamps were cycled from 05:00 to 21:00 for 16 cycles per day of 45-min lamps-on and 15-min lamps-off. All lamps were commercially available, non-agriculture specific lamps. No LED lamps failed during 416 d of testing, while the four incandescent lamp failures occurred at an average of 1968 h, and three of four CFLA lamps failures occurred at an average of 2640 h, and one of four CFLB lamps failed at 3312 h while the remainder of the CFLB lamps were operating at the conclusion of the test. The accelerated testing protocol may have influenced the early failures for some lamp types. Both types of CFLand LED lamps evaluated were more energy efficient than incandescent lamps and showed similar reduced relative energy usage compared to incandescent lamps (CFLA: 28%, CFLB: 30%, and LED 33%). CFL and LED lamps showed illuminance degradation during testing; the LED lamps tested showed the greatest decrease.
机译:照明会影响家禽的行为,生长和繁殖。人工照明广泛用于饲养家禽。该项目的目的是确定在典型的禽舍条件下替代低功率灯泡的可靠性,照度和功耗。在禽舍中使用了照明测试设备,以便同时加速耐久性测试,以测试三种灯的四种重复情况(一种白炽灯,两种不同类型的紧凑型荧光灯(CFLA和B)和一种灯)发光二极管灯(LED)]。灯从05:00到21:00进行循环,每天进行45分钟的灯打开和15分钟的灯关闭的16个循环。所有的灯都是可商购的,非农业专用的灯。在416 d的测试期间,没有LED灯出现故障,平均在1968 h发生了四只白炽灯故障,在平均2640 h时发生了四只CFLA灯中的三只,在3312 h时出现了四只CFLB灯中的一盏CFLB灯的其余部分在测试结束时仍在工作。加速测试协议可能已经影响了某些灯泡的早期故障。评估的两种类型的CFL和LED灯均比白炽灯具有更高的能源效率,并且与白炽灯(CFLA:28%,CFLB:30%和LED 33%)相比,显示出类似的相对能耗降低。 CFL和LED灯在测试过程中显示照度下降;测试的LED灯显示最大的下降。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号