Nano-thermometers with thermo-sensitive polymer grafted USPIOs behaving as positive contrast agents in low-field MRI

机译:Nano-thermometers和热敏性聚合物嫁接USPIOs行为看作是积极的对比代理在低场核磁共振

获取原文
获取原文并翻译 | 示例

摘要

Two commercial statistical copolymers of ethylene oxide and propylene oxide, Jeffamine (R) M-2005 (PEO5-st-PPO37) and M-2070 (PEO46-st-PPO13), exhibiting lower critical solution temperature (LCST) in water, were grafted onto the surface of ultra-small superparamagnetic iron oxide nanoparticles (USPIOs) using silanization and amide-bond coupling reactions. The LCSTs of the polymers in solution were measured by dynamic light scattering (DLS) and nuclear magnetic resonance (NMR). In accordance with the compositions of EO vs. PO, the transition temperature was measured to be 22 +/- 2 degrees C for M-2005 by both DLS and NMR, while the LCST was much higher, 52 +/- 2 degrees C, for M-2070 (a second transition was also detected above 80 degrees C by NMR in that case, ascribed to the full dehydration of chains at the molecular level). The resulting polymer-grafted USPIOs exhibit a temperature-responsive colloidal behaviour, their surface reversibly changing from hydrophilic below LCST to hydrophobic above it. This phenomenon was utilised to design thermo-sensitive contrast agents for MRI. Transverse relaxivities (r(2)) of the USPIO@PEO5-st-PPO37 core-shell nanoparticles were measured at 8.25, 20, 60, and 300 MHz. Nuclear magnetic resonance dispersion (NMRD) profiles, giving longitudinal relaxivities (r(1)) between 0.01 and 60 MHz, were acquired at temperatures ranging from 15 to 50 degrees C. For all tested frequencies except 300 MHz, both r(1) and r(2) decrease with temperature and show an inflection point at 25 degrees C, near the LCST. To illustrate the interest of such polymer-coated USPIOs for MRI thermometry, sample tubes were imaged on both low-field (8.25 MHz/0.194 Tesla) and high-field (300 MHz/7.05 Tesla) MRI scanners with either T-1-or T-2*-weighted spin echo sequences. The positive contrast on low-field MR images and the perfect linearity of the signal with a T-2*-weighted sequence over the entire temperature range 15-50 degrees C render these LCST polymer coated USPIOs interesting positive contrast agents, also working as "nano-thermometers".
机译:两个商业统计乙烯的共聚物氧化和氧化丙烯,Jeffamine (R)的m - 2005(PEO5-st-PPO37)和M-2070 (PEO46-st-PPO13),表现出低临界溶解温度(LCST)在水里,接枝到表面上超小超顺磁性氧化铁使用硅烷化和纳米颗粒(USPIOs)酰胺键偶联反应。聚合物在溶液中被动态测量光散射(DLS)和核磁共振(核磁共振)。EO与PO的成分,过渡温度测量是22 + / - 2度m - 2005的NMR和DLS LCST时要高得多,52 + / - 2度,m - 2070(第二个过渡也检测到超过80度由NMR在这种情况下,归因于充分脱水在分子链级别)。表现出鬼屋方面的胶体行为,其表面可逆地改变亲水下面LCST疏水。这一现象被利用的设计温为磁共振成像造影剂。横向relaxivities (r (2))USPIO@PEO5-st-PPO37核壳纳米粒子是震级为8.25级,20岁,60岁,300 MHz。磁共振弥散(NMRD)配置文件,给纵向relaxivities (r(1))之间0.01和60 MHz,获得了温度从15到50度c .所有测试频率300 MHz除外,r(1)和(2)降低温度和显示一个拐点点25摄氏度,LCST附近。说明这种种的兴趣USPIOs MRI测温法,样品管在低场成像(8.25 MHz / 0.194特斯拉)和轨迹(300 MHz / 7.05特斯拉)核磁共振扫描仪与T-1-or 2 *三自旋回波序列。图像和信号的完美的线性用2 *三在整个序列温度范围15-50度呈现这些LCST聚合物涂层USPIOs有趣的积极造影剂,也工作“nano-thermometers”。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号