The purpose of this study was to develop and evaluate an automated spray pattern measurement system which utilized digital liquid level sensors to quantify the coefficient of variation (CV) for different nozzle configurations. The overall system was designed to measure nozzle effluent in 25 mm divisions from 38.1 to 76.2 cm in width for multiple nozzle configurations with a total patternator surface width of 3.05 m. The patternator surface and data collection system were designed and developed to achieve three primary goals: patternator surface division accuracy, data collection system accuracy, and data collection system repeatability. Patternator surface measurements indicated an average standard deviation of approximately 0.1 mm (0.4%) which would not contribute significantly to spray pattern CV estimates. To quantify the measurement accuracy, the automated system was compared to manual data collection using weights collected from graduated cylinders. Statistical analysis revealed no difference (p > 0.05) between CV estimates from the manual and automated data collection methods. The average difference in CV between the two methods was 0.15% which considered 12 tests per method. Repeatability was also a primary concern, the standard deviation among CV values for tests conducted with the automated system was only 0.35%. The evaluation of the system provided confidence that suitable results would be acquired for different nozzle configurations consisting of acceptable or relatively poor spray patterns.
机译:这项研究的目的是开发和评估一种自动喷雾模式测量系统,该系统利用数字液位传感器来量化不同喷嘴配置的变异系数(CV)。整个系统的设计目的是测量喷头流出物,该喷头流出物的宽度为38.1到76.2厘米(25毫米),适用于多种喷嘴配置,图案形成器总表面宽度为3.05 m。设计和开发图案形成器表面和数据收集系统以实现三个主要目标:图案形成器表面划分精度,数据收集系统精度和数据收集系统可重复性。图案形成器的表面测量结果表明平均标准偏差约为0.1毫米(0.4%),这不会显着影响喷涂图案的CV估算。为了量化测量精度,将自动系统与使用从刻度量筒中收集的重量的手动数据收集进行了比较。统计分析表明,手动和自动数据收集方法的CV估算值之间没有差异(p> 0.05)。两种方法之间的CV平均差异为0.15%,这考虑到每种方法12次测试。重复性也是主要考虑因素,使用自动化系统进行的测试的CV值之间的标准偏差仅为0.35%。对系统的评估提供了信心,即对于由可接受或相对较差的喷雾模式组成的不同喷嘴配置,可以获得适当的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号