首页> 外文期刊>Nanoscale >Silica-coated bismuth sulfide nanorods as multimodal contrast agents for a non-invasive visualization of the gastrointestinal tract
【24h】

Silica-coated bismuth sulfide nanorods as multimodal contrast agents for a non-invasive visualization of the gastrointestinal tract

机译:Silica-coated硫化铋纳米棒多通道为非侵入性造影剂胃肠道的可视化

获取原文
获取原文并翻译 | 示例

摘要

Non-invasive and real-time imaging of the gastrointestinal (GI) tract is particularly desirable for research and clinical studies of patients with symptoms arising from gastrointestinal diseases. Here, we designed and fabricated silica-coated bismuth sulfide nanorods (Bi2S3@SiO2 NRs) for a non-invasive spatial-temporally imaging of the GI tract. The Bi2S3 NRs were synthesized by a facile solvothermal method and then coated with a SiO2 layer to improve their biocompatibility and stability in the harsh environments of the GI tract, such as the stomach and the small intestine. Due to their strong X-ray- and near infrared-absorption abilities, we demonstrate that, following oral administration in mice, the Bi2S3@SiO2 NRs can be used as a dual-modal contrast agent for the real-time and non-invasive visualization of NRs distribution and the GI tract via both X-ray computed tomography (CT) and photoacoustic tomography (PAT) techniques. Importantly, integration of PAT with CT provides complementary information on anatomical details with high spatial resolution. In addition, we use Caenorhabditis Elegans (C. Elegans) as a simple model organism to investigate the biological response of Bi2S3@SiO2 NRs by oral administration. The results indicate that these NRs can pass through the GI tract of C. Elegans without inducing notable toxicological effects. The above results suggest that Bi2S3@SiO2 NRs pave an alternative way for the fabrication of multi-modal contrast agents which integrate CT and PAT modalities for a direct and non-invasive visualization of the GI tract with low toxicity.
机译:非侵入性和实时成像的特别是胃肠通道理想的研究和临床研究患者因症状胃肠道疾病。装配式silica-coated硫化铋纳米棒非侵入性(Bi2S3@SiO2关系)胃肠道的时空成像。Bi2S3 NRs合成肤浅solvothermal方法,然后涂上了二氧化矽层来改善其生物相容性和胃肠道的稳定性在严酷的环境中束,如胃和小肠。红外吸收能力,我们将演示在小鼠口服后,可以用作dual-modal Bi2S3@SiO2评分实时和非侵入性的对比剂NRs分布的可视化和胃肠道通过x射线计算机断层扫描(CT)和呼吸道光声层析成像技术(PAT)。重要的是,帕特与CT提供的集成互补的解剖细节信息高空间分辨率。秀丽隐杆线虫(秀丽隐杆线虫)作为一个简单的生物模型对生物进行调查响应Bi2S3@SiO2 NRs的口腔管理。关系,可以通过胃肠道线虫没有诱导显著的毒性效应。上述结果表明,Bi2S3@SiO2关系为制造的另一种方式多模式集成CT造影剂和帕特直接和非侵入性的方法可视化的胃肠道毒性较低。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号