首页> 外文期刊>Transactions of the Institution of Mining and Metallurgy, Section A. Mining Technology >Stress corrosion testing of roof bolt grade 60 steel in simulated underground coal mine atmosphere
【24h】

Stress corrosion testing of roof bolt grade 60 steel in simulated underground coal mine atmosphere

机译:屋顶螺栓的应力腐蚀测试成绩60钢在模拟地下煤矿大气

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Corrosion of roof bolts in underground mine environments could have an adverse impact on ground control, which is directly related to workforce safety. Past studies state that stress corrosion cracking (SCC) of roof bolts is a significant problem in underground coal mines, resulting in premature bolt failures. However, it has not been seriously studied in U.S. underground coal mines. As a preliminary study, the most common roof bolt material used in U.S. mines, ASTM A 615 Grade 60 steel, was studied under stress corrosion conditions. ASTM G30 standard was applied to achieve this and tested in the simulated coal mine conditions. SCC was observed on samples that were tested for 180 days. Chloride SCC (CISCC) was found to be the corrosion mechanism resulting in cracks from the EDS data. This paper mainly discusses the test protocol, shortcomings of this preliminary testing and makes recommendations based on the observations and results.
机译:腐蚀的屋顶螺栓在地下矿井环境可能造成负面的影响地面控制,直接相关员工的安全。腐蚀开裂(SCC)的屋顶螺栓是一个在地下煤矿重大问题,导致过早螺栓失败。没有认真研究过美国吗地下煤矿。在美国最常见的屋顶螺栓材料使用矿山、ASTM 615年级60钢进行了研究在应力腐蚀条件下。标准被用来实现这个目标和测试在模拟煤矿条件。180年观察到样本上进行了测试天。腐蚀机理导致的裂缝EDS数据。协议,这个初步的缺点测试和提出建议的基础上观察和结果。