Comparative short-term in vitro analysis of mutans streptococci adhesion on esthetic, nickel-titanium, and stainless-steel arch wires

机译:变形,链球菌在美学,镍钛合金和不锈钢弓丝上的粘附力的短期比较分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objective: To test the hypothesis that there are no differences in mutans streptococci (MS) adhesion between esthetic and metallic orthodontic arch wires based on their surface characteristics. Materials and Methods: Surface roughness (Ra) and apparent surface free energy (SFE) were measured for six wires-four esthetic, one nickel-titanium (NiTi), and one stainless-steel (SS)- using profilometry and dynamic contact angle analysis, respectively. The amount of MS (Streptococcus mutans and Streptococcus sobrinus) adhering to the wires was quantified using the colony-counting method. The surfaces, coating layers, and MS adhesion were also observed by scanning electron microscopy. Statistical significance was set at P , .05. Results: The Ra values of the esthetic wires were significantly different from one another depending on the coating method (P , .05). The NiTi wire showed the highest SFE, followed by the SS wire and then the four esthetic wires. The NiTi wires produced a significantly higher MS adhesion than did the SS wires (P , .05). The esthetic wires showed significantly lower MS adhesions than did the NiTi wire (P , .05). Pearson correlation analyses found moderate significant positive correlations between the SFE and the S mutans and S sobrinus adhesions (r 5 .636/.427, P , .001/P 5 .001, respectively). Conclusions: The hypothesis is rejected. This study indicates that some esthetic coatings on NiTi alloy might reduce MS adhesion in vitro in the short term. (Angle Orthod. 2014;84:680-686.)
机译:目的:为了验证以下假设,根据其表面特性,美观和金属正畸弓丝之间的变形链球菌(MS)粘附力没有差异。材料和方法:使用轮廓测量法和动态接触角分析法测量了六种线材-四种美学线,一种镍钛(NiTi)和一种不锈钢(SS)-的表面粗糙度(Ra)和表观表面自由能(SFE)。 , 分别。使用菌落计数法对附着在电线上的MS(变形链球菌和sobrinus链霉菌)的数量进行定量。还通过扫描电子显微镜观察了表面,涂层和MS粘附。统计显着性设定为P,0.05。结果:美容线的Ra值根据涂覆方法的不同而彼此显着不同(P,.05)。 NiTi线的SFE最高,其次是SS线,然后是四根美学线。 NiTi丝产生的MS附着力比SS丝高(P,.05)。与NiTi线相比,美学线的MS附着力显着降低(P,.05)。皮尔森相关性分析发现SFE与变形链球菌和S氏br疮粘连之间存在中等显着的正相关(分别为r 5 .636 / .427,P,.001 / P 5 .001)。结论:该假设被拒绝。这项研究表明,NiTi合金上的一些美学涂层可能会在短期内降低MS的附着力。 (角度矫正.2014; 84:680-686。)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号