首页> 外文期刊>Angle Orthodontist >Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets.
【24h】

Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets.

机译:两种正畸胶粘剂与自结扎带和传统托槽之间的抗剪强度比较。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. MATERIALS AND METHODS: Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT) with a conventional (Orthos) and a self-ligating bracket (Damon 2), respectively. Group 3 used a light-cured primer (Orthosolo) and a light-cured adhesive (Blugloo) with a self-ligating bracket (Damon 2). The specimens were stored in distilled water at 37 degrees C for 40 +/- 2 hours, after which they were debonded and inspected for Adhesive Remnant Index (ARI) scoring. RESULTS: The mean shear bond strength was 15.2 MPa for group 1, 23.2 MPa for group 2, and 24.8 MPa for group 3. A one-way analysis of variance and post hoc Tukey test showed significant differences in bond strength (P < .001) between group 1 andgroups 2 and 3 but no significant difference (P > .05) between groups 2 and 3. A Weibull analysis demonstrated that all three groups provided sufficient bond strength with over 90% survival rate at normal masticatory and orthodontic force levels. A Kruskal-Wallis test showed no significant difference (P > .05) in ARI scores among all three groups. CONCLUSIONS: All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.
机译:目的:使用两种类型的托槽来评估和比较两种粘合剂的剪切粘结强度:常规托槽和自结扎托槽系统。材料与方法:收集六十个提取的人类前磨牙。前磨牙被随机分为三组,每组20颗牙齿。这三组都是直接键合的。第1组和第2组分别使用光固化的粘合剂和底漆(Transbond XT)以及常规的(Orthos)和自结扎支架(Damon 2)。第3组使用具有自连接托槽(Damon 2)的光固化底漆(Orthosolo)和光固化粘合剂(Blugloo)。将样品在37摄氏度的蒸馏水中保存40 +/- 2小时,然后将其脱粘并检查粘合残余指数(ARI)得分。结果:第一组的平均剪切粘结强度为15.2 MPa,第二组的平均剪切粘结强度为23.2 MPa,第三组的平均剪切粘结强度为24.8 MPa。单向方差分析和事后Tukey测试表明,粘结强度存在显着差异(P <.001 )在第1组与第2组和第3组之间存在差异,但在第2组和第3组之间没有显着差异(P> .05)。Weibull分析表明,在正常的咀嚼和正畸力水平下,三组均可提供足够的粘结强度,且存活率超过90%。 Kruskal-Wallis检验显示,所有三组之间的ARI得分均无显着差异(P> .05)。结论:所有三组均表现出临床可接受的结合强度。 Damon 2自连接支架在使用的两种粘合剂体系中均表现出令人满意的体外粘合强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号