首页> 外文期刊>Proceedings of the Society for Experimental Mechanics >Effect of Sample Pre-Contact on the Experimental Evaluation of Cartilage Mechanical Properties
【24h】

Effect of Sample Pre-Contact on the Experimental Evaluation of Cartilage Mechanical Properties

机译:样本Pre-Contact对实验的影响对软骨力学性能的评价

获取原文
获取原文并翻译 | 示例
           

摘要

Mechanical characterization of articular cartilage has been widely analyzed in the literature, both experimentally and numerically, since load support (strength) and deformability (compliance) are among the most important physiological functions of this living tissue. They are also important indicators of cartilage degradation and regeneration. Cartilage elastic properties (Young's Modulus, Aggregate Modulus and Poisson ratio) are usually determined experimentally by uniaxial confined and unconfined compression tests. Relevant differences can be found in the literature for these variables even when similar experimental protocols are used. Before starting the actual compression test, a pre-contact protocol has to be carried out in order to obtain optimum contact between the test tool and the cartilage sample. The aim of this work is to analyze the effect of sample pre-contact on the test results comparing three different protocols available in the literature (predeformation of 4 and 10% of the total thickness of the sample and a preload equivalent to 12.5 KPa). The implementation of these protocols achieved contact, but only the predeformation allowed normalized experiments and ensured repeatability of the tests. Additionally, under the predeformation protocols, the results and trends for uniaxial compression tests were consistent with the cartilage physiological function. However, for 10% predeformation, the experimental data showed maximum dispersion at the final stress levels. The statistical treatment determined significant differences between the 10% predeformation and the preload results (Aggregate Modulus and Poisson ratio), defining them as non comparable protocols. Finally, a new pre-contact protocol is proposed introducing an initial approximation point between the test tool and the cartilage sample, and followed by a predeformation of 4% for confined and unconfined tests.
机译:关节软骨的力学特性被广泛分析文献中,两个实验和数值,因为负载支持(强度)和可变形性(合规)是最重要的生理吗这个活组织的功能。软骨退化和的重要指标再生。(杨氏模量、骨料弹性模量和泊松比)通常是决定实验单轴约束和无侧限抗压强度测试。文学为这些变量即使相似实验使用的协议。pre-contact实际压缩试验协议是为了获得执行优化和测试工具之间的联系软骨样例。分析样本pre-contact在的效果测试结果比较三种不同的协议可用在文献中(预变形的4和样本的总厚度的10%预加载相当于12.5 KPa)。实现这些协议的实现接触,但只允许预变形归一化实验,确保可重复性的测试。预变形的协议,结果和趋势单轴压缩试验是一致的软骨生理功能。然而,对于10%的预变形,实验数据显示最大分散在最后压力水平。决定之间的显著差异10%的预变形,预加载的结果(骨料弹性模量和泊松比),定义非类似的协议。pre-contact协议提出了引入一个测试工具之间的初始近似点和软骨样,后跟一个4%的预变形承压和非承压测试。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号