首页> 外文期刊>Angle Orthodontist >Reliability of the integrated radiograph-photograph method to obtain natural head position in cephalometric diagnosis.
【24h】

Reliability of the integrated radiograph-photograph method to obtain natural head position in cephalometric diagnosis.

机译:头颅诊断中综合的X射线照片法获得自然头部位置的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To introduce a simple and reliable method to reorient lateral radiographs to the natural head position (NHP) according to standardized photographs made at NHP. MATERIAL AND METHODS: The study has two parts. In the first part, 45 patients were randomly selected from a patient cohort. Photographs (at NHP) and cephalograms from each patient were taken and assessed in two sessions by two observers. The time between the first and the second session was 5 weeks. The repeatability of profile measurements on cephalograms compared with standardized photographs of the same patient was determined; in the second part, the repeatability of three superimposing protocols (ie, the soft tissue N/subnasale line [V-line], the esthetic line [E-line], and a proposed nose best fit line [N-line]) was compared for the reorientation of the cephalogram according to the photographs made at the NHP. RESULTS: Our results showed that the integration of radiographs and photographs is an objective and reliable method to obtain NHP in lateral cephalograms. The N-line is a reproducible and stable reference line for the reorientation of radiographs to obtain NHP. CONCLUSION: Reorientation of radiographs according to standardized photographs made at the NHP is a reliable and objective method to standardize the radiographs at the NHP for cephalometric analysis. The N-line is a reproducible and stable reference line for the reorientation. It is preferred over the V-line or even E-line, especially when the radiographs and photographs are taken at different sessions or at different treatment stages.
机译:目的:根据NHP的标准化照片,介绍一种简单可靠的方法来将侧向X光片重新定向到自然头部位置(NHP)。材料与方法:本研究分为两个部分。在第一部分中,从患者队列中随机选择45名患者。每位患者的照片(在NHP拍摄)和头颅图均由两名观察员分两次进行评估。第一和第二节之间的时间为5周。确定了与相同患者的标准照片相比,在头颅图上进行的轮廓测量的可重复性;在第二部分中,三种叠加方案(即软组织N /鼻下线[V-line],美学线[E-line]和建议的鼻子最佳贴合线[N-line])的可重复性为根据在NHP拍摄的照片,对头颅图的重新定位进行了比较。结果:我们的研究结果表明,X光片和照片的整合是一种客观,可靠的获取侧位脑电图中NHP的方法。 N线是用于重新定位X射线照片以获得NHP的可复制且稳定的参考线。结论:根据NHP制作的标准化照片重新定位X射线照片是一种可靠,客观的方法,用于标准化NHP的X射线照片以进行头颅测量。 N线是重新定向的可复制且稳定的参考线。它比V线甚至E线更可取,特别是当X光片和照片是在不同的疗程或不同的治疗阶段拍摄时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号