Flowable composites for bonding orthodontic retainers.

机译:用于粘结正畸固定器的可流动复合材料。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To test the null hypothesis that there are no statistically significant differences between flowables and an orthodontic adhesive tested in terms of shear bond strength (SBS) and pullout resistance. MATERIALS AND METHODS: To test the SBS of Light Bond, FlowTain, Filtek Supreme, and Tetric Flow were applied to the enamel surfaces of 15 teeth. Using matrices for application, each composite material was cured for 40 seconds and subjected to SBS testing. To test pullout resistance, 15 samples were prepared for each composite in which a wire was embedded; then the composite was cured for 40 seconds. Later, the ends of the wire were drawn up and tensile stress was applied until the resin failed. Findings were analyzed using an ANOVA and a Tukey HSD test. RESULTS: The SBS values for Light Bond, FlowTain, Filtek Supreme, and Tetric Flow were 19.0 +/- 10.9, 14.7 +/- 9.3, 22.4 +/- 16.3, and 16.8 +/- 11.8 MPa, respectively, and mean pullout values were 42.2 +/- 13.0, 24.0 +/- 6.9, 26.3 +/- 9.4, and 33.8 +/- 18.0 N, respectively. No statistically significant differences were found among the groups in terms of SBS (P > .05). On the other hand, Light Bond yielded significantly higher pullout values compared with the flowables Filtek Supreme and Flow-Tain (P < .01). However, there were no significant differences among the pullout values of flowables, nor between Light Bond and Tetric Flow (P > .05). CONCLUSIONS: The hypothesis is rejected. Light Bond yielded significantly higher pullout values compared with the flowables Filtek Supreme and FlowTain. However, flowable composites provided satisfactory SBS and wire pullout values, comparable to a standard orthodontic resin, and therefore can be used as an alternative for direct bonding of lingual retainers.
机译:目的:为了检验零假设,即在剪切粘结强度(SBS)和抗拔强度方面,流动性材料与正畸粘合剂之间没有统计学上的显着差异。材料与方法:为了测试轻质粘结的SBS,将FlowTain,Filtek Supreme和Tetric Flow涂在15颗牙齿的牙釉质表面上。使用基质进行涂覆,将每种复合材料固化40秒,并进行SBS测试。为了测试抗拔出性,对于每个嵌入导线的复合材料,准备15个样品。然后将复合材料固化40秒。之后,将金属丝的末端拉起并施加拉伸应力,直到树脂失效。使用方差分析和Tukey HSD测试对结果进行分析。结果:轻质粘接剂,FlowTain,Filtek Supreme和Tetric Flow的SBS值分别为19.0 +/- 10.9、14.7 +/- 9.3、22.4 +/- 16.3和16.8 +/- 11.8 MPa,以及平均拔出值分别为42.2 +/- 13.0 N,24.0 +/- 6.9、26.3 +/- 9.4和33.8 +/- 18.0 N.在SBS方面,各组之间未发现统计学上的显着差异(P> .05)。另一方面,与流动性Filtek Supreme和Flow-Tain(P <.01)相比,Light Bond产生的拉拔值明显更高。但是,流动性的拉出值之间,轻质粘结性和四性流动性之间没有显着差异(P> .05)。结论:该假设被拒绝。与流动性Filtek Supreme和FlowTain相比,Light Bond产生的拉拔值明显更高。但是,与标准的正畸树脂相比,可流动的复合材料提供了令人满意的SBS和导线拔出值,因此可以用作直接粘合舌头固定器的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号