首页> 外文期刊>Annals of work exposures and health. >Development of Membrane Hollow Fiber for Determination of Maleic Anhydride in Ambient Air as a Field Sampler
【24h】

Development of Membrane Hollow Fiber for Determination of Maleic Anhydride in Ambient Air as a Field Sampler

机译:开发膜中空纤维,以确定环境空气中的马来酸酐作为现场采样器

获取原文
获取原文并翻译 | 示例
       

摘要

This research develops a rapid method for sampling and analysis of maleic anhydride (MA) in air using a one-step hollow fiber (HF) membrane in the liquid phase followed by high-performance liquid chromatography. A sampling chamber was prepared for sampling of MA with HF-supported de-ionized water absorbency. Several important parameters, such as sampling flow rate, sampling time, and breakthrough volume (BTV), were optimized at different concentrations using a central composite design. The results showed that sampling could be performed at the maximum period of 4 h with a flow rate of 1 mL min-1 for different concentrations (in the range of 0.05-2 mg m(-3)). The BTV was 240 mL. The relative standard deviations for the repeatability of interday and intraday were 7-10%, 10%, respectively, and the pooled standard deviation was 0.088. The limit of detection and limit of quantitation values were 0.033 and 0.060 mg m(-3), respectively. Moreover, our findings revealed that the samples could be stored in sealed HF flexible plastic tubes in a cover at refrigerator temperature (4 degrees C) for up to 7 days. The HF method was compared with method number 3512 National Institute Occupational Safety and Health for determination of MA. There was a good correlation (R-2 = 0.99) between the two methods at a concentration of 0.05 to 2 mg m(-3) in the laboratory and the average concentration of MA for both methods was 0.11 mg m(-3) in the ambient air at an adhesive manufacturer. Our findings indicated that the proposed HF can act as a reliable, rapid, and effective approach for sampling of MA in workplaces.
机译:这项研究开发了一种快速的方法,用于在液相中使用一步空心纤维(HF)膜在空气中在空气中进行采样和分析的方法,然后进行高性能液相色谱。制备采样室,用HF支持的去离子水吸收性对MA进行采样。使用中央复合材料设计以不同的浓度优化了几个重要参数,例如采样流速,采样时间和突破量(BTV)。结果表明,对于不同浓度(在0.05-2 mg m(-3)范围内),可以在4小时的最大周期进行采样,而流速为1 mL min-1。 BTV为240毫升。日间和日内重复性的相对标准偏差分别为7-10%,10%,汇总的标准偏差为0.088。检测限和定量值的极限分别为0.033和0.060 mg m(-3)。此外,我们的发现表明,这些样品可以在冰箱温度(4度C)的盖上密封的HF柔性塑料管中存储长达7天。将HF方法与国立研究所职业安全和健康的方法进行了比较,以确定MA。两种方法之间的相关性良好(R-2 = 0.99),实验室的浓度为0.05至2 mg m(-3),两种方法的平均MA浓度为0.11 mg m(-3)粘合剂制造商的环境空气。我们的发现表明,拟议的HF可以作为在工作场所中MA采样的可靠,快速和有效的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号