首页> 外文期刊>Annals of work exposures and health. >Evaluation of Exposure Assessment Tools under REACH: Part I-Tier 1 Tools
【24h】

Evaluation of Exposure Assessment Tools under REACH: Part I-Tier 1 Tools

机译:触及评估工具的评估:I-Tier 1 Part 1工具

获取原文
获取原文并翻译 | 示例
           

摘要

Tier 1 occupational exposure assessment tools recommended for use under the Registration, Evaluation, Authorization, and restriction of CHemicals (REACH) were evaluated using newly collected measurement data. Evaluated tools included the ECETOC TRAv2 and TRAv3, MEASEv1.02.01, and EMKG-EXPO-TOOL. Fifty-three exposure situations (ESs) based on tasks/chemicals were developed from National Institute for Occupational Safety and Health field surveys. During the field surveys, high quality contextual information required for evaluating the tools was also collected. For each ES, applicable tools were then used to generate exposure estimates using a consensus approach. Among 53 ESs, only those related to an exposure category of liquids with vapor pressure (VP) > 10 Pa had sufficient numbers of exposure measurements (42 ESs with n = 251 for TRAv2 and TRAv3 and 40 ESs with n = 243 for EMKG-EXPO-TOOL) to be considered in detail. The results for other exposure categories (aqueous solutions, liquids with VP 10 Pa, metal processing, powders, and solid objects) had insufficient measurement to allow detailed analyses (results listed in the Supplementary File). Overall, EMKG-EXPO-TOOL generated more conservative results than TRAv2 and TRAv3 for liquids with high VP. This finding is at least partly due to the fact that the EMKG-EXPO-TOOL only considers pure substances and not mixtures of chemical agents. For 34 out of 40 ESs available for chemicals with VP > 10 Pa, the liquid was a mixture rather than a pure substance. TRAv3 was less conservative than TRAv2, probably due to additional refinement of some input parameters. The percentages of exposure measurement results exceeding the corresponding tool estimates for liquids with VP > 10 Pa by process category and by input parameters were always higher for TRAv3 compared to those for TRAv2. Although the conclusions of this study are limited to liquids with VP > 10 Pa and few process categories, this study utilized the most transparent contextual information compared to previous studies, reducing uncertainty from assumptions for unknown input parameters. A further validation is recommended by collecting sufficient exposure data covering other exposure categories and all process categories under REACH.
机译:使用新收集的测量数据评估了建议在注册,评估,授权和限制下使用的职业暴露评估工具。评估的工具包括ECETOC TRAV2和TRAV3,MESEV1.02.01和EMKG-EXPO-Tool。国家职业安全与健康现场调查研究所开发了基于任务/化学品的53个暴露情况(ESS)。在现场调查中,还收集了评估工具所需的高质量上下文信息。对于每个ES,然后使用适用的工具使用共识方法来生成曝光估计。在53个ESS中,只有与蒸气压的液体(VP)> 10 PA相关的液体类别有足够数量的暴露测量(TRAV2和TRAV2和TRAV3和40 ESS的n = 251和n = 243的EMKG-Expo的42 ESS测量值(42 ESS) - 工具)要详细考虑。其他暴露类别(水溶液,具有VP 10 PA的液体,金属加工,粉末和固体物体)的结果不足以允许详细分析(补充文件中列出的结果)。总体而言,EMKG-Expo-Tool比TRAV2和TRAV3对具有高VP的液体产生了更保守的结果。这一发现至少部分是由于以下事实:EMKG-Expo-Tool仅考虑纯物质,而不考虑化学剂的混合物。对于具有VP> 10 PA的化学物质的40个ESS中的34个,液体是混合物而不是纯物质。 TRAV3不如TRAV2保守,可能是由于某些输入参数的额外细化。与TRAV2相比,TRAV3的暴露测量结果百分比超过了TRAV3的VP> 10 PA液体的相应刀具估计值。尽管这项研究的结论仅限于VP> 10 PA且几乎没有过程类别的液体,但与以前的研究相比,本研究利用了最透明的上下文信息,从而减少了未知输入参数的假设的不确定性。建议通过收集足够的暴露数据来涵盖其他暴露类别和所有过程类别,建议进一步验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号