...
首页> 外文期刊>American Journal of Sports Medicine >Effect of electron beam irradiation on biomechanical properties of patellar tendon allografts in anterior cruciate ligament reconstruction.
【24h】

Effect of electron beam irradiation on biomechanical properties of patellar tendon allografts in anterior cruciate ligament reconstruction.

机译:电子束辐照对all前韧带重建中tell肌腱同种异体移植物生物力学性能的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Sterilization of anterior cruciate ligament (ACL) allografts is an important prerequisite to prevent disease transmission. However, mechanical tissue properties are compromised by most current sterilization procedures, so that uncompromised sterilization of allografts is difficult to achieve. Hypothesis/ PURPOSE: The aim of this study was to evaluate the effect of the novel electron beam sterilization procedure on the biomechanical properties of human patellar tendon allografts at various irradiation dosages. Electron beam sterilization may be an appropriate alternative to gamma sterilization. STUDY DESIGN: Controlled laboratory study. METHODS: Thirty-two human 10-mm wide bone-patellar tendon-bone grafts were randomized into 4 groups of sterilization with 15, 25, or 34 kGy of electron beam irradiation, respectively. The grafts' biomechanical properties were evaluated at time zero. Unsterilized grafts functioned as controls. Biomechanical properties were analyzed during cyclic and load-to-failure testing. RESULTS: Strain and cyclic elongation response showed no significant differences between the groups. Electron beam irradiation had no significant effect on stiffness and failure load with the exception of 34 kGy, which resulted in a significant decrease in failure load (1300.6 +/- 229.2 N) compared with unsterilized grafts (1630.5 +/- 331.1 N). CONCLUSION: This study showed that electron beam might be an appropriate alternative in sterilization of patellar tendon allografts with minimal effect on mechanical properties of tendon grafts in vitro. Future studies will have to evaluate the effect of the process on the biological properties of allografts in vitro and in vivo. CLINICAL RELEVANCE: Terminal sterilization of patellar tendon allografts with electron beam irradiation can ensure higher safety of transplanted grafts and hence improve patient safety and acceptance.
机译:背景:前交叉韧带(ACL)同种异体的灭菌是预防疾病传播的重要前提。但是,大多数当前的灭菌程序会损害机械组织的性能,因此很难实现同种异体移植的无害灭菌。假设/目的:这项研究的目的是评估新型电子束灭菌程序在不同照射剂量下对pa骨同种异体肌腱生物力学特性的影响。电子束灭菌可能是伽马灭菌的合适替代方法。研究设计:受控实验室研究。方法:将32例人类10毫米宽的human骨腱-骨移植物随机分为4组,分别用15、25、34 kGy电子束照射进行灭菌。在零时评估移植物的生物力学性能。未灭菌的移植物用作对照。在循环测试和负载失效测试期间分析了生物力学性能。结果:应变和循环伸长响应在两组之间没有显着差异。电子束辐照对刚度和破坏载荷没有显着影响,只有34 kGy,与未灭菌的移植物(1630.5 +/- 331.1 N)相比,导致破坏载荷(1300.6 +/- 229.2 N)显着降低。结论:这项研究表明,电子束可能是sterilization骨肌腱同种异体移植物灭菌的合适替代方法,其对体外肌腱移植物力学性能的影响最小。未来的研究将必须评估该过程对同种异体移植物体外和体内生物学特性的影响。临床意义:用电子束辐照对pa腱同种异体移植物进行终末灭菌可确保移植物具有更高的安全性,从而提高患者的安全性和接受度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号