Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake

机译:在冠状动脉血管造影中使用320行CT的低管电压,低浓度对比剂的应用:图像质量,辐射剂量和碘摄入量的评估

获取原文
获取原文并翻译 | 示例
           

摘要

abstract_textpThe effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography, radiation dose and iodine intake was evaluated. A total of 121 patients with body mass index (BMI) 26 kg/m(2) and heart rate (HR) 70 beats/min were randomly divided into four groups: group A (n=31, 80 kVp, 270 mgI/mL); group B (n=33, 100 kVp, 270 mgI/mL); group C (n=30, 100 kVp, 320 mgI/mL); group D (n=27, 100 kVp, 400 mgI/mL). The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group. The CT values and SD values of the aortic root (AR), subcutaneous fat, left coronary artery opening (LCA), and right coronary artery opening (RCA) were measured in all groups, the signal-to-noise ratio (SNR) and contrast noise ratio (CNR) were calculated, and effective radiation dose and iodine intake were recorded. The subjective assessment for image quality was performed by two physicians using a 4-point scale. The results were compared using the one-way ANOVA and rank sum tests. The image quality of the four groups met the clinical diagnostic requirements. The CT values of AR in groups A, B, C, and D were 537.6 +/- 71.4, 447.2 +/- 81.9, 445.2 +/- 64.9 and 518.5 +/- 94.9 Hu, respectively, with no significant difference between group A and group D, or between group B and group C, while CT values in groups B and C were significantly lower than those in groups A and D (P0.05). In groups A, B, C, and D, the LCA SNR values were 22.7 +/- 9.1, 23.3 +/- 9.1, 23.3 +/- 7.7 and 26.6 +/- 8.9, and the RCA CNR values were 26.9 +/- 9.8, 28.5 +/- 11.4, 27.7 +/- 8.8 and 32.1 +/- 10.6, respectively. The AR visual scores in groups A, B, C and D were 3.8 +/- 0.2, 3.9 +/- 0.3, 3.9 +/- 0.3 and 4.0 +/- 0.3, respectively. There were no significant differences in SNR, CNR and visual score among the four groups (P0.05). The radiation doses in groups A, B, C and D were 2.6 +/- 1.4, 3.6 +/- 1.8, 4.9 +/- 3.5 and 4.9 +/- 2.8 mSv, respectively. The radiation dose in group A was significantly less than that in the rest three groups (P0.05). The iodine intakes in groups A, B, C and D were 14.9 +/- 1.5, 15.0 +/- 1.5, 17.7 +/- 2.0 and 18.1 +/- 2.5 g, respectively. There was no significant difference in the intake of iodine between groups C and D, or between groups A and B, while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D (P0.05). It was concluded that for patients with low BMI and controlled HR, compared to 100 kVp tube voltage combined with multiple concentration contrast agents, 80 kVp combined with 270 mgI/mL contrast agent is enough to ensure the quality of the images, and can reduce the radiation dose significantly, while reducing the amount of iodine intake notably, thus reducing the incidence of adverse reaction./p/abstract_text
机译:& Abstract_text&&& p&评估了低压和低浓度对比剂对冠状动脉血管造影,辐射剂量和碘摄入量的图像质量的影响。总共121例体重指数(BMI)< 26 kg/m(2)和心率(HR)< 70 BEATS/min被随机分为四组:A组(n = 31,80 kvp, 270 mgi/ml); B组(n = 33,100 kVp,270 mgi/ml); C组(n = 30,100 kVp,320 mgi/ml); D组(n = 27,100 kVp,400 mgi/ml)。每个组都采用了自动电流调制系统和用于重建的迭代算法。在所有组中测量了主动脉根(AR),皮下脂肪,左冠状动脉开口(LCA)和右冠状动脉开口(RCA)的CT值和SD值(左动脉开放)(RCA),所有组,信噪比(SNR)和计算对比噪声比(CNR),并记录有效的辐射剂量和碘摄入量。两位医生使用4分制进行了对图像质量的主观评估。使用单向方差分析和秩和测试比较结果。这四组的图像质量满足了临床诊断要求。 A,B,C和D组中AR的CT值为537.6 +/- 71.4,447.2 +/- 81.9,445.2 +/- 64.9和518.5 +/- 94.9 HU,A组A组之间没有显着差异D组和B组和C组之间,而B组和C组中的CT值显着低于A和D组中的CT值(P< 0.05)。在A,B,C和D组中,LCA SNR值为22.7 +/- 9.1,23.3 +/- 9.1,23.3 +/- 7.7和26.6 +/- 8.9,RCA CNR值为26.9 +/-- 9.8,28.5 +/- 11.4,27.7 +/- 8.8和32.1 +/- 10.6。 A,B,C和D组的AR视觉分数分别为3.8 +/- 0.2、3.9 +/- 0.3、3.9 +/- 0.3和4.0 +/- 0.3。四组之间的SNR,CNR和视觉评分没有显着差异(P> 0.05)。 A,B,C和D组中的辐射剂量分别为2.6 +/- 1.4、3.6 +/- 1.8、4.9 +/- 3.5和4.9 +/- 2.8 msv。 A组中的辐射剂量明显小于其余三组(P< 0.05)。 A,B,C和D组中的碘摄入量分别为14.9 +/- 1.5、15.0 +/- 1.5、17.7 +/- 2.0和18.1 +/- 2.5 g。 C组和D组之间的碘摄入量没有显着差异,而与C组相比,A和B组中的碘摄入量显着降低(P< 0.05)。得出的结论是,对于低BMI和受控HR的患者,与100 kVp管电压结合了多个浓度对比剂,80 kVP与270 mgi/ml的对比剂结合在一起足以确保图像的质量,并可以降低降低图像的质量辐射剂量显着减少了碘摄入量,从而降低了不良反应的发生率。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号