首页> 外文期刊>ANZ journal of surgery >Transfer function index: is it a reliable method for vein graft surveillance?
【24h】

Transfer function index: is it a reliable method for vein graft surveillance?

机译:传递函数指数:这是一种可靠的静脉移植物监测方法吗?

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

INTRODUCTION: Duplex ultrasound scanning is currently the best available non-invasive method for vein graft surveillance. However, it is expensive and its results are highly operator dependent. The aim of the present study is to compare, another non-invasive method of graft surveillance, the transfer function index (TFI), with duplex ultrasound scanning in identifying significant stenoses in infrainguinal saphenous vein bypass grafts. METHODS: Initially a retrospective pilot study was carried out between 1 January and 30 June 2002. Patients were identified from the vascular surgical operation database. The ultrasound report and TFI result of each patient were reviewed. Then a prospective comparative study was carried out between 1 July and 31 December 2002. Duplex ultrasound and TFI studies were undertaken at the 3 month interval. Comparisons were made between the accuracy and predictive value of ultrasound versus TFI in assessing significant graft stenosis. RESULTS: In the present retrospective study TFI measurement was significantly lower in the at-risk grafts than in the normal grafts (P = 0.001). In the prospective group TFI was again found to be significantly lower in the at-risk group (mean TFI 0.86) than in the normal group (mean TFI 1.064, P = 0.001). The sensitivity and specificity of the TFI were 92% and 97%, respectively. The accuracy of TFI was calculated to be 98%. CONCLUSION: TFI is an accurate non-invasive method of vascular graft surveillance. TFI can be carried out in the vascular clinic and is quick and inexpensive. Normally TFI could replace duplex ultrasound surveillance, with ultrasound being reserved for those with an abnormal TFI.
机译:简介:双面超声扫描是目前用于静脉移植物监测的最佳可用非侵入性方法。但是,它很昂贵,其结果在很大程度上取决于操作员。本研究的目的是比较另一种非侵入性的移植物监视方法,即转移功能指数(TFI),与双工超声扫描在确定鞘内大隐静脉旁路移植术中的明显狭窄方面进行比较。方法:最初在2002年1月1日至6月30日之间进行了一项回顾性先导研究。从血管外科手术数据库中识别出患者。回顾每位患者的超声报告和TFI结果。然后在2002年7月1日至12月31日期间进行了一项前瞻性比较研究。每3个月进行一次双重超声和TFI研究。超声与TFI在评估明显的移植狭窄方面的准确性和预测价值之间进行了比较。结果:在本回顾性研究中,有风险的移植物的TFI测量值显着低于正常移植物(P = 0.001)。在前瞻性组中,再次发现高风险组的TFI(平均TFI为0.86)明显低于正常组(平均TFI为1.064,P = 0.001)。 TFI的敏感性和特异性分别为92%和97%。 TFI的准确性经计算为98%。结论:TFI是一种准确的无创血管移植监测方法。 TFI可以在血管诊所进行,并且快速,廉价。通常,TFI可以代替双工超声监视,而超声保留给那些异常TFI的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号