首页> 外文期刊>Acta physiologica Scandinavica >Extramuscular myofascial force transmission within the rat anterior tibial compartment: proximo-distal differences in muscle force.
【24h】

Extramuscular myofascial force transmission within the rat anterior tibial compartment: proximo-distal differences in muscle force.

机译:大鼠胫前肌腔内的肌筋膜肌力传递:肌肉力的近端-远端差异。

获取原文
获取原文并翻译 | 示例
           

摘要

Intramuscular connective tissues are continuous to extramuscular connective tissues. If force is transmitted there, differences should be present between force at proximal and distal attachments of muscles. Extensor digitorum longus (EDL), tibialis anterior (TA), and extensor hallucis longus muscles (EHL) were excited simultaneously and maximally. Only EDL length was changed, exclusively by moving the position of its proximal tendon. Distal force exerted by TA + EHL complex was not affected significantly. Proximal and distal EDL isometric force were not equal for most EDL lengths: Fprox - Fdist ranged from 0 to approximately +22.7% of Fprox at higher lengths and from 0 to approximately -24.5% at the lowest lengths. It is concluded that extramuscular connections transmit force from muscle. Significant proximo-distal differences of EDL force remained after repeated measurements, regardless of length order, although their length dependence was altered. Measurements of both proximal and distal EDL force were highly reproducible, if EDL did not attain higher lengths than target length. After being active at high lengths, proximal and distal length-force curves were altered at low lengths but not for the highest length range. Extensor digitorum longus length-active force hysteresis was present for proximal as well as distal EDL measurements with increasing and decreasing isometric length order. Further isolating EDL removed the proximo-distal difference for active EDL force. However a decreased difference for passive EDL force remained, which was ascribed to remaining extramuscular connective tissue linkages. It is concluded that extramuscular myofascial force transmission is an important feature of muscle that is not isolated from its surrounding tissues.
机译:肌内结缔组织与肌外结缔组织是连续的。如果将力传递到那里,则在肌肉的近端和远端连接处的力之间应该存在差异。同时并最大程度地刺激了趾长伸肌(EDL),胫前肌(TA)和拇长伸肌(EHL)。仅通过移动近端肌腱的位置即可更改EDL长度。 TA + EHL复合体施加的远侧力未受到明显影响。对于大多数EDL长度,近端和远端EDL等距力均不相等:Fprox-Fdist在较大长度下的范围为Fprox的0到大约+ 22.7%,在最小长度下为0到大约-24.5%。结论是,肌肉外连接从肌肉传递力。重复测量后,无论长度顺序如何,EDL力的远近差异仍然很大,尽管它们的长度相关性已改变。如果EDL的长度不超过目标长度,则可高度重复测量近端和远端EDL力。在高长度下活动后,近端和远端长度-力曲线在低长度下改变,但在最大长度范围内不改变。对于近端和远端EDL测量,随着等长长度顺序的增加和减少,存在指趾长肌长度-主动力滞后现象。进一步隔离EDL消除了有效EDL力的近距离差异。然而,被动EDL力的差异仍然减小,这归因于剩余的肌外结缔组织联系。结论是,肌外肌筋膜力传递是肌肉的重要特征,其并非与其周围组织隔离。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号