Comparative study of two generations of the Complior device for aortic pulse wave velocity measurements.

机译:两代Complior装置用于主动脉脉搏波速度测量的比较研究。

获取原文
获取原文并翻译 | 示例
           

摘要

INTRODUCTION: The purpose of this study was to evaluate intraobserver and interobserver reproducibility of carotid-femoral pulse wave velocity (PWV) with the Complior method, by comparing two generations of the device and the manual method. METHODS: We studied 31 participants (9 women) with a mean age of 47.67+/-12.55 years, who were submitted to sequential measures of carotid-femoral PWV by two experienced operators. The evaluations were made by randomly switching between the manual method, the Complior first generation, and the Complior SP (third generation). RESULTS: The analysis of concordance of measurements of PWV showed strong intraobserver and interobserver correlations. The intraobserver correlation coefficients were 0.984, 0.977, and 0.966, respectively, for manual evaluation, the Complior first generation, and the Complior SP (P<0.0001). In the case of interobserver reproducibility, we found correlations of 0.940, 0.979, and 0.974, respectively, for manual evaluation, the Complior first generation, and Complior SP (P<0.0001). Good indicators of reproducibility were also a withdrawal of the Bland-Altman analysis, with most values within 2 standard deviations. The mean difference+/-SD for intraobserver and interobserver agreement was -0.006+/-0.05 and -0.06+/-0.09 for manual determination; -0.02+/-0.06 and -0.04+/-0.06 for Complior first generation; and 0.16+/-0.09 and 0.15+/-0.07 for the Complior SP. CONCLUSION: The data showed a high reproducibility of the Complior method, documented by excellent correlations and low mean differences in measurements within and between observers. These data showed unequivocally that this method met the quality requirements for its inclusion in integrated clinical follow-up programs.
机译:简介:本研究的目的是通过比较两代装置和手动方法,以Complior方法评估颈内股动脉的观察者内和观察者间的可重复性(PWV)。方法:我们研究了31名平均年龄为47.67 +/- 12.55岁的参与者(9名女性),他们由两名经验丰富的操作员接受了颈股动脉PWV的连续测量。通过在手动方法,Complior第一代和Complior SP(第三代)之间随机切换来进行评估。结果:PWV的测量一致性的分析表明,观察者间和观察者间的相关性很强。对于手动评估,Complior第一代和Complior SP,观察者内相关系数分别为0.984、0.977和0.966。(P <0.0001)。在观察者间可重复性的情况下,我们发现手动评估,Complior第一代和Complior SP的相关性分别为0.940、0.979和0.974(P <0.0001)。 Bland-Altman分析也撤消了重复性的良好指示,大多数值均在2个标准差内。观察者内部和观察者之间一致性的平均差+/- SD为-0.006 +/- 0.05,而人工确定的为-0.06 +/- 0.09; Complior第一代为-0.02 +/- 0.06和-0.04 +/- 0.06;而Complior SP则为0.16 +/- 0.09和0.15 +/- 0.07。结论:数据显示Complior方法具有很高的重现性,其观察者之间和观察者之间的测量具有极好的相关性和较低的平均差异,从而证明了这一点。这些数据明确表明,该方法符合将其纳入综合临床随访计划的质量要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号