...
首页> 外文期刊>Clinical implant dentistry and related research >Primary Stability Determination by Means of Insertion Torque and RFA in a Sample of 4,135 Implants
【24h】

Primary Stability Determination by Means of Insertion Torque and RFA in a Sample of 4,135 Implants

机译:在4,135个植入物样品中,通过插入扭矩和RFA的一级稳定性测定

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: The aims of the present study are to evaluate the primary stability of a sample of 4,135 implants and to investigate the correlations between primary stability and mechanical characteristic of the implant and bone density at insertion time. Material and Methods: The study was conducted from March 2002 to January 2009 at a private practice in Bologna (Italy). Patients were eligible for the study if they needed the insertion of single or multiple implants. Bone density, length, and diameter of each implant were recorded. During surgery for each implant, peak insertion torque (IT) was recorded; the resonance frequency analysis (RFA) values were also collected. Finally, it was recorded whether an implant was lost or removed at an early stage (within 6months from insertion surgery). Results: A total of 1,045 consecutive patients were included in the study. A total of 4,135 of implants were inserted. The sample presented 1,184 implants inserted in a postextractive site. The mean peak IT was 34.82±19.36. The mean RFA was 71.57±10.63 implant stability quotient. Spearman correlation analysis shows the presence of a weak positive correlation between IT and RFA. The statistical analysis shows a relevant dependency between IT and bone quality and a very weak dependency between RFA and bone quality. Again, the statistical analysis shows a quite weak correlation between length or diameter and IT, but it shows a relevant correlation between length and RFA. Postextractive implants presented a higher mean IT and a lower RFA compared with implants inserted in healed sites. Twenty-eight (0.7%) implants were considered to have failed and removed within 6months. Conclusions: The results show that the implants studied obtain a good primary stability with a standard protocol. The IT and RFA appear as two independent features of primary stability. Data show that only IT is influenced by bone density as well as only RFA is correlated to the length of implants used. Finally, it is possible to obtain a good primary stability also in postextractive sites.
机译:目的:本研究的目的是评估4,135个植入物样品的主要稳定性,并研究插入时植入物和骨密度的一级稳定性与机械特征之间的相关性。材料和方法:该研究是从2002年3月到2009年1月在博洛尼亚(意大利)的一项私人执业中进行的。如果患者需要插入单个或多个植入物,则有资格进行研究。记录每种植入物的骨密度,长度和直径。在每种植入物的手术过程中,记录了峰值插入扭矩(IT);还收集了共振频率分析(RFA)值。最后,记录了在早期(插入手术的6个月内)是否丢失或去除植入物。结果:该研究中总共包括1,045例连续患者。总共插入了4,135个植入物。样品提出了1,184个植入物,该植入物插入了提取后部位。平均峰值为34.82±19.36。平均RFA为71.57±10.63植入物稳定性商。 Spearman相关分析显示IT与RFA之间存在弱正相关。统计分析显示了IT与骨质质量之间的相关依赖性以及RFA和骨质质量之间的依赖性非常弱。同样,统计分析显示长度或直径之间的相关性非常弱,但显示长度与RFA之间的相关相关性。与在治愈位点插入的植入物相比,提取后植入物具有更高的平均值和更低的RFA。 28(0.7%)植入物被认为在6个月内失败和去除。结论:结果表明,所研究的植入物获得具有标准协议的良好初级稳定性。 IT和RFA作为主要稳定性的两个独立特征。数据表明,只有它受骨密度的影响,并且只有RFA与所用植入物的长度相关。最后,也可以在提取后位点获得良好的主要稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号