首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Zeolitic imidazolate framework-8/ fluorinated graphene coated SiO2 composites for pipette tip solid-phase extraction of chlorophenols in environmental and food samples
【24h】

Zeolitic imidazolate framework-8/ fluorinated graphene coated SiO2 composites for pipette tip solid-phase extraction of chlorophenols in environmental and food samples

机译:沸石Imidazolate框架-8 /氟化石墨烯涂覆的SiO2复合材料,用于移液管尖端固相萃取环保和食品样品中氯酚的萃取

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In this work, a novel composite adsorbent was successfully prepared by zeolite imidazolate framework-8/ fluorinated graphene layer-by-layer covalently bonded on SiO2 microspheres, and followed to be packed into micro pipette tip for extraction of trace chlorophenols prior to their detection by high performance liquid chromatography (HPLC). The morphology and structure of adsorbent material was characterized by field emission scanning electron microscopy with energy dispersive spectrometer, X-ray diffraction, and N-2 adsorption. The parameters including the amount of adsorbent, sampling volume, sampling rate, sample pH, and desorption solvent affected the extraction performance was systematically investigated by pipette tip solid-phase extraction (PT-SPE) coupled with HPLC analysis. Under the optimized condition, the linearity of this method ranged from 20 to 2000 ng mL (1) for chlorophenols (CPs) with determination coefficient higher than 0.99. The limit of detection (at a signal-to-noise ratio of 3) were in the range 2-20 ng mL (1) for tap water and black tea drinks, 0.2-2 mu g g (1) for honey. The relative recoveries of the CPs from spiked samples ranged from 71.8% to 104.7%, with relative standard deviations less than 6.2%. The filled extraction tube exhibited good stability and reproducibility. The proposed method has been successfully used to detect CPs in water and drinks with satisfactory recoveries.
机译:在本研究中,一种新型的复合吸附剂由咪唑分子筛骨架-8/氟化石墨烯层层共价键合在SiO2微球上成功制备,然后填充到微吸管尖端,用于提取痕量氯酚,然后通过高效液相色谱(HPLC)检测。用场发射扫描电子显微镜、能谱仪、X射线衍射仪和N-2吸附仪对吸附材料的形貌和结构进行了表征。采用液相色谱-吸管尖端固相萃取(PT-SPE)联用技术,系统研究了吸附剂用量、进样体积、进样速率、样品pH值和解吸溶剂等参数对萃取性能的影响。在优化条件下,该方法对氯酚(CPs)的线性范围为20-2000ng mL(1),测定系数大于0.99。自来水和红茶饮料的检测限(信噪比为3)为2-20 ng mL(1),蜂蜜的检测限为0.2-2μg(1)。加标样品中CPs的相对回收率为71.8%-104.7%,相对标准偏差小于6.2%。填充的萃取管具有良好的稳定性和重现性。该方法已成功用于水和饮料中CPs的检测,回收率令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号